{"id":6872,"date":"2026-11-11T14:11:04","date_gmt":"2026-11-11T06:11:04","guid":{"rendered":"https:\/\/www.clin-ele.com\/?p=6872"},"modified":"2026-11-11T14:11:04","modified_gmt":"2026-11-11T06:11:04","slug":"ac-contactor-selection-motor-lighting","status":"publish","type":"post","link":"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting","title":{"rendered":"How to Select the Right AC Contactor for Motor and Lighting Loads"},"content":{"rendered":"<p>Un <a href=\"https:\/\/www.clin-ele.com\/fr\/product-category\/power-distribution-control-series\/ac-contactor-series\/\" target=\"_blank\" rel=\"noopener noreferrer\">AC contactor<\/a> is the electromechanical workhorse that switches motors, heaters, and lighting loads from a low-power control circuit. Size or specify the wrong one and you face coil burnout, contact welding, nuisance tripping, or premature failure in the field. This guide is written for panel builders, OEMs, and specifying engineers who need a repeatable method for AC contactor selection across the two most common load types: three-phase motors (AC-3 duty) and lighting (AC-5b duty). Get the duty category, current rating, and coil supply right, and the contactor will run for millions of operations.<\/p>\n<p><img decoding=\"async\" style=\"display: block; margin: 24px auto; max-width: 100%; height: auto; border-radius: 6px;\" src=\"https:\/\/www.clin-ele.com\/wp-content\/uploads\/2025\/05\/CJX2-09.jpg\" alt=\"AC contactor switching a motor and lighting load inside a control panel\" \/><\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table des mati\u00e8res<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table des mati\u00e8res\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Basculer<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting\/#Why_AC_Contactor_Selection_Starts_With_Duty_Category\" >Why AC Contactor Selection Starts With Duty Category<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting\/#How_AC-3_Motor_Duty_Drives_the_Sizing\" >How AC-3 Motor Duty Drives the Sizing<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting\/#How_AC-5b_Lighting_Duty_Differs\" >How AC-5b Lighting Duty Differs<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting\/#Sizing_Checklist_for_Motor_and_Lighting_Loads\" >Sizing Checklist for Motor and Lighting Loads<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting\/#Coil_Voltage_and_Control-Supply_Matching\" >Coil Voltage and Control-Supply Matching<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting\/#Building_a_Coordinated_Protected_Panel\" >Building a Coordinated, Protected Panel<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting\/#Common_AC_Contactor_Selection_Mistakes\" >Common AC Contactor Selection Mistakes<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting\/#Wiring_and_Installation_Notes\" >Wiring and Installation Notes<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting\/#Troubleshooting_Contact_Failures\" >Troubleshooting Contact Failures<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting\/#Matching_the_Contactor_to_the_Rest_of_the_Panel\" >Matching the Contactor to the Rest of the Panel<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting\/#Frequently_Asked_Questions\" >Frequently Asked Questions<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting\/#How_do_I_size_an_AC_contactor_for_a_motor\" >How do I size an AC contactor for a motor?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting\/#Can_I_use_a_motor_contactor_for_LED_lighting\" >Can I use a motor contactor for LED lighting?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting\/#Do_I_need_UL_508_certification_on_the_contactor\" >Do I need UL 508 certification on the contactor?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting\/#Specify_the_Right_AC_Contactor_Every_Time\" >Specify the Right AC Contactor Every Time<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/www.clin-ele.com\/fr\/ac-contactor-selection-motor-lighting\/#Related_Resources\" >Related Resources<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Why_AC_Contactor_Selection_Starts_With_Duty_Category\"><\/span>Why AC Contactor Selection Starts With Duty Category<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The single biggest mistake in contactor sizing is treating every load the same. IEC 60947-4-1 defines utilization categories that describe both the current level and the switching severity. For AC contactor selection, two categories dominate your work:<\/p>\n<ul>\n<li><strong>AC-3<\/strong> \u2014 squirrel-cage motors: switching during normal running (the motor is already up to speed when de-energized, and started from rest). This is the default for pumps, fans, compressors, and conveyors.<\/li>\n<li><strong>AC-4<\/strong> \u2014 motors with frequent inching\/plugging or rapid reversing, where the contactor breaks high making-and-breaking currents. Ratings here are much lower than AC-3 for the same frame.<\/li>\n<li><strong>AC-5b<\/strong> \u2014 electrical discharge lamps (including LED and fluorescent ballasts) and similar lighting loads with inrush.<\/li>\n<li><strong>AC-1<\/strong> \u2014 non-inductive or mildly inductive resistive loads such as heaters, where current and making\/breaking are equal.<\/li>\n<\/ul>\n<p>Because a contactor&#8217;s rated current depends on the category, a 40\u00a0A AC-3 contactor may only be rated around 25\u201330\u00a0A in AC-4. Always read the rating table for your specific duty before quoting.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_AC-3_Motor_Duty_Drives_the_Sizing\"><\/span>How AC-3 Motor Duty Drives the Sizing<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For motors, start from the nameplate full-load current (FLA). A three-phase motor draws roughly 1.25\u20131.5\u00a0A per horsepower at 400\u2013460 V, but always use the nameplate, not a rule of thumb. Size the contactor&#8217;s AC-3 rated current at least 10\u201325% above FLA to absorb starting inrush (typically 6\u20138\u00d7 FLA for a few hundred milliseconds) and thermal margin. A 15\u00a0kW \/ 400 V motor with ~30\u00a0A FLA, for instance, comfortably uses a 40\u00a0A AC-3 contactor. For heavy starting (high-inertia loads, compressors), lean toward the next frame size. If the application involves frequent reversing or plugging, drop to the AC-4 rating column\u2014or specify a dedicated reversing contactor set.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_AC-5b_Lighting_Duty_Differs\"><\/span>How AC-5b Lighting Duty Differs<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Lighting is deceptively harsh. Incandescent and halogen lamps have a cold-filament inrush of 10\u201315\u00d7 steady current for the first cycle; modern <strong>LED drivers<\/strong> and electronic ballasts can also present significant capacitive inrush and harmonic current. That is why lighting calls for AC-5b categorization rather than AC-1. When you select an AC contactor for lighting, size it to the lamp&#8217;s steady current but confirm the inrush rating, and for large LED banks consider a contactor one frame size larger or a dedicated lighting contactor. Never assume a motor-rated contactor is automatically fine for a lighting panel\u2014the duty curves differ.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Sizing_Checklist_for_Motor_and_Lighting_Loads\"><\/span>Sizing Checklist for Motor and Lighting Loads<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Use this table as your specification worksheet. Each step maps to a line on the datasheet:<\/p>\n<table style=\"width: 100%; border-collapse: collapse; margin: 18px 0; font-size: 15px;\">\n<tbody>\n<tr style=\"background-color: #f4f4f4;\">\n<th style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\">\u00c9tape<\/th>\n<th style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\">Action<\/th>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 10px;\">1. Duty category<\/td>\n<td style=\"border: 1px solid #ddd; padding: 10px;\">AC-3 for motors, AC-5b for lighting, AC-1 for heaters, AC-4 for plugging<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 10px;\">2. Current rating<\/td>\n<td style=\"border: 1px solid #ddd; padding: 10px;\">\u2265 load current plus inrush and thermal margin (10\u201325%)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 10px;\">3. Coil voltage<\/td>\n<td style=\"border: 1px solid #ddd; padding: 10px;\">Match control supply: 24 V DC, 110 V AC, 230 V AC<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 10px;\">4. Poles<\/td>\n<td style=\"border: 1px solid #ddd; padding: 10px;\">3-pole for three-phase motor\/lighting; add pole or separate relay for control<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 10px;\">5. Coordination<\/td>\n<td style=\"border: 1px solid #ddd; padding: 10px;\">Pair with a <a href=\"https:\/\/www.clin-ele.com\/fr\/product-category\/power-distribution-control-series\/control-and-protection-switch-series\/\" target=\"_blank\" rel=\"noopener noreferrer\">CPS<\/a> or upstream breaker for fault protection<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 10px;\">6. Certifications<\/td>\n<td style=\"border: 1px solid #ddd; padding: 10px;\">CE, RoHS, IEC 60947, UL 508 where required<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span class=\"ez-toc-section\" id=\"Coil_Voltage_and_Control-Supply_Matching\"><\/span>Coil Voltage and Control-Supply Matching<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The coil is where many startup failures originate. A 230 V AC coil on a 24 V DC supply will not pull in; a 24 V DC coil on a noisy supply may chatter. Standardize the coil voltage to your panel&#8217;s control transformer\u201424 V DC and 230 V AC are the most common\u2014and, where the supply is unreliable, consider a wide-range or DC coil with surge suppression. For B2B distributors, stocking the popular coil voltages (24 V DC and 230 V AC) in the common current frames covers most quotes without ballooning SKU count.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Building_a_Coordinated_Protected_Panel\"><\/span>Building a Coordinated, Protected Panel<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A contactor switches; it does not protect. Every AC contactor selection must be paired with upstream fault protection and, ideally, overload protection. You can use a separate <a href=\"https:\/\/www.clin-ele.com\/fr\/product-category\/power-distribution-control-series\/\" target=\"_blank\" rel=\"noopener noreferrer\">power-distribution control<\/a> breaker plus an overload relay, or consolidate with a <a href=\"https:\/\/www.clin-ele.com\/fr\/product-category\/power-distribution-control-series\/control-and-protection-switch-series\/\" target=\"_blank\" rel=\"noopener noreferrer\">control and protection switch (CPS)<\/a> that combines switching and protection in one device. Either way, verify selective coordination so a motor fault trips the local device rather than the main incoming breaker\u2014keeping the rest of the plant online. C-Lin ELEC&#8217;s AC contactor series ships CE\/UL certified across the common coil and current frames and pairs cleanly with its CPS and distribution range for a tidy, serviceable board.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Common_AC_Contactor_Selection_Mistakes\"><\/span>Common AC Contactor Selection Mistakes<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><strong>Using AC-3 rating for an AC-4 job<\/strong> \u2014 rapid reversing wears contacts far faster than the AC-3 table implies.<\/li>\n<li><strong>Ignoring LED inrush<\/strong> \u2014 sizing a lighting contactor to steady current alone causes contact welding.<\/li>\n<li><strong>Wrong coil voltage<\/strong> \u2014 the most frequent cause of &#8220;contactor won&#8217;t pull in&#8221; callbacks.<\/li>\n<li><strong>No overload protection<\/strong> \u2014 a contactor is not a protector; pair it deliberately.<\/li>\n<li><strong>Skipping certification check<\/strong> \u2014 shipping a non-UL contactor into a North American panel fails inspection.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Wiring_and_Installation_Notes\"><\/span>Wiring and Installation Notes<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Correct wiring protects the contactor and the load it serves. Route the coil control wires away from the power terminals and from VFD or contactor-coil wiring to avoid induced pickup that makes the coil chatter. For a 24 V DC coil, fit a freewheel diode or suppressor across the coil so the collapsing field does not damage the PLC transistor; for AC coils, a varistor or RC snubber serves the same purpose. Torque both the line\/load power terminals and the coil terminals to the manufacturer&#8217;s values\u2014loose power terminals overheat and weld, while loose coil terminals cause intermittent drop-out. Keep the three-phase poles balanced and, where the contactor feeds a motor, verify the phase sequence before the first energization so the machine turns the intended direction.<\/p>\n<p>If the application is lighting, separate the contactor from dimmer or LED-driver heat and confirm the AC-5b rating covers the connected inrush; for very large lamp banks, stage the load with two contactors or a soft-start to limit the combined inrush current the distribution board must tolerate. These details are spelled out in the datasheet, and following them is what delivers the millions of operations the contactor is rated for.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Troubleshooting_Contact_Failures\"><\/span>Troubleshooting Contact Failures<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Most contactor problems trace back to selection or wiring rather than the device itself. A contactor that will not pull in usually has the wrong coil voltage, a dropped control supply, or a chattering DC coil without suppression. One that welds its contacts on a lighting load was almost certainly undersized for the lamp inrush\u2014revisit the AC-5b rating. Premature contact erosion on a motor duty points to an AC-4 application being run on an AC-3 frame, or to mechanical jamming from misaligned busbar connections. Overheating at the terminals means loose torque or undersized conductors. When a contactor fails to drop out and the load stays energized, suspect a welded contact or a coil stuck closed\u2014both demand immediate isolation and replacement, and both reinforce why coordinated upstream protection from a <a href=\"https:\/\/www.clin-ele.com\/fr\/product-category\/power-distribution-control-series\/control-and-protection-switch-series\/\" target=\"_blank\" rel=\"noopener noreferrer\">control and protection switch<\/a> or breaker must always back the contactor. A methodical AC contactor selection up front prevents the majority of these field callbacks.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Matching_the_Contactor_to_the_Rest_of_the_Panel\"><\/span>Matching the Contactor to the Rest of the Panel<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>AC contactor selection does not happen in isolation; the contactor must sit coherently within the wider <a href=\"https:\/\/www.clin-ele.com\/fr\/product-category\/power-distribution-control-series\/\" target=\"_blank\" rel=\"noopener noreferrer\">power-distribution control<\/a> assembly. Size the upstream protection so it grades with the contactor&#8217;s own rating, place surge protection where transient-prone loads exist, and keep the control wiring on a clean supply so the coil is immune to noise. For heaters and resistive loads, consider whether a solid-state relay might outlast a contactor where silent, frequent switching is required\u2014though the contactor remains the cost-effective default for motor and lighting duty. Distributors benefit from presenting the contactor, CPS, and protection devices as one coordinated offer, because panel builders prefer to source a matched, certified family from a single manufacturer with one datasheet set and one lead-time promise.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions\"><\/span>Frequently Asked Questions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"How_do_I_size_an_AC_contactor_for_a_motor\"><\/span>How do I size an AC contactor for a motor?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Start from the motor&#8217;s nameplate FLA, choose the AC-3 rating column, and select a contactor rated at least 10\u201325% above FLA to cover starting inrush. For frequent reversing or plugging, use the lower AC-4 rating instead.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Can_I_use_a_motor_contactor_for_LED_lighting\"><\/span>Can I use a motor contactor for LED lighting?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Only after checking the AC-5b lighting rating and the lamp&#8217;s inrush. LED driver inrush can be significant, so size to the lighting duty column and consider the next frame size for large banks.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Do_I_need_UL_508_certification_on_the_contactor\"><\/span>Do I need UL 508 certification on the contactor?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>For North American panels, yes\u2014UL 508 listing is expected by inspectors. CE and RoHS cover the European market; always confirm the certificate scope matches the exact contactor frame and coil you are buying.<\/p>\n<div style=\"background-color: #d0121b; color: #ffffff; padding: 24px 28px; border-radius: 6px; margin: 28px 0;\">\n<h3 style=\"color: #ffffff; margin: 0 0 12px 0; font-size: 20px; line-height: 1.3;\"><span class=\"ez-toc-section\" id=\"Specify_the_Right_AC_Contactor_Every_Time\"><\/span>Specify the Right AC Contactor Every Time<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p style=\"color: #ffffff; margin: 0 0 16px 0; line-height: 1.6;\">C-Lin ELEC AC contactors cover motor (AC-3) and lighting (AC-5b) duty with CE\/UL certification and matched control voltages, plus coordinated CPS and distribution devices. Request the sizing table, datasheet, and a quote for your panel.<\/p>\n<p><a style=\"display: inline-block; background-color: #ffffff; color: #d0121b; padding: 12px 24px; border-radius: 4px; text-decoration: none; font-weight: 600;\" href=\"https:\/\/www.clin-ele.com\/fr\/product-category\/power-distribution-control-series\/ac-contactor-series\/\" target=\"_blank\" rel=\"noopener noreferrer\">Browse AC Contactors<\/a><\/p>\n<\/div>\n<h2><span class=\"ez-toc-section\" id=\"Related_Resources\"><\/span>Related Resources<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><a href=\"https:\/\/www.clin-ele.com\/fr\/product-category\/power-distribution-control-series\/control-and-protection-switch-series\/\" target=\"_blank\" rel=\"noopener noreferrer\">Control and Protection Switches<\/a><\/li>\n<li><a href=\"https:\/\/www.clin-ele.com\/fr\/product-category\/power-distribution-control-series\/\" target=\"_blank\" rel=\"noopener noreferrer\">S\u00e9rie de contr\u00f4le de la distribution de puissance<\/a><\/li>\n<li><a href=\"https:\/\/www.clin-ele.com\/fr\/product-category\/relay-series\/\" target=\"_blank\" rel=\"noopener noreferrer\">C-Lin Relay Series Overview<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Size it right or it fails. Select AC contactors for motor and lighting loads by duty, current and coil.<\/p>","protected":false},"author":3,"featured_media":7001,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"rank_math_title":"How to Select an AC Contactor for Motor & Lighting | C-Lin","rank_math_description":"Size AC contactors for motor (AC-3) and lighting (AC-5b) loads. Duty, current, coil and coordination checklist.","rank_math_focus_keyword":"","rank_math_canonical_url":"","rank_math_facebook_title":"","rank_math_facebook_description":"","rank_math_facebook_image":"","rank_math_twitter_title":"","rank_math_twitter_description":"","rank_math_twitter_image":"","rank_math_twitter_card_type":"","rank_math_twitter_use_facebook":"","rank_math_pillar_content":"","rank_math_robots":[],"rank_math_primary_category":0,"footnotes":""},"categories":[23],"tags":[],"class_list":["post-6872","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technical-articles"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.clin-ele.com\/fr\/wp-json\/wp\/v2\/posts\/6872","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.clin-ele.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.clin-ele.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.clin-ele.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.clin-ele.com\/fr\/wp-json\/wp\/v2\/comments?post=6872"}],"version-history":[{"count":6,"href":"https:\/\/www.clin-ele.com\/fr\/wp-json\/wp\/v2\/posts\/6872\/revisions"}],"predecessor-version":[{"id":7000,"href":"https:\/\/www.clin-ele.com\/fr\/wp-json\/wp\/v2\/posts\/6872\/revisions\/7000"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.clin-ele.com\/fr\/wp-json\/wp\/v2\/media\/7001"}],"wp:attachment":[{"href":"https:\/\/www.clin-ele.com\/fr\/wp-json\/wp\/v2\/media?parent=6872"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.clin-ele.com\/fr\/wp-json\/wp\/v2\/categories?post=6872"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.clin-ele.com\/fr\/wp-json\/wp\/v2\/tags?post=6872"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}