MOQ : 60
Working power supply: DC24V; AC24V, AC220V, AC380V
Delay range: 0.5s~3600s
Repeat error: ≤1%
Working mode: HHS4 (JS14A, JS20): power-on delay
HHS4C (JS20/03): power-on delay with instantaneous action
HHS4G: release delay
Contact form: HHS4, HHS4G: two groups of delay
HHS4C: one group of delay and one group of instantaneous action
Contact capacity: 3A AC250V (resistive)
Dimensions: 45×82×83mm
Opening size: 56-2×Φ4.5mm
Installation method: device type or 35mm guide rail type
Working power supply: DC24V; AC24V, AC220V, AC380V
Delay range: 0.99s, 9.9s, 99s, 9.9m, 99m, 99h
99.9s, 999s, 99.9m, 999m, 999h
Repeat error: ≤1%
Working mode: power-on delay
Contact form: two sets of delay contacts
Contact capacity: 3A AC250V (resistive)
Dimensions: 45×82×90mm
Opening size: 56-2×Φ4.5mm
Installation method: device type or 35mm guide rail type
Working power supply: DC24V; AC24V, AC220V, AC380V
Delay range: 9.9s, 99s, 99.9s, 199s
Repeat error: ≤5%
Working mode: power-off delay
Contact form: two sets of delay contacts
Contact capacity: 3A AC250V (resistive)
Dimensions: 45×82×90mm
Opening size: 56-2×Φ4.5mm
Installation method: device type and 35mm guide rail type
| Specification | HHS4 | HHS4C | HHS4G | HHS4PA |
| Operating power | AC380V,AC220V,AC127V,AC110V,AC36V,AC24V, 50Hz;DC24V | |||
| Movement Forms | Power-on delay | Power-on delay with momentary contact | Release delay | Power-on delay |
| Delay Range | 0.1s~1s、0.5s~5s、1s~10s、3s~30s、6s~60s、12s~120s、18s-180s、30s-300s、60s~600s、90s~900s、120s~1200s、180s~1800s、360s~3600s | 0.1s-99h | ||
| Number of contacts | Delay 2 conversion | Delay 1 transition with reset pause | Delay 2 conversion | Delay 2 conversion; delay 1 conversion, instantaneous 1 conversion |
| Repetition error | Er<1% when the delay range is greater than 1s; Dr<50ms when the delay range is less than 1s. | |||
| Contact capacity | 3A AC250V (resistive) | |||
| Temperature range | -5°-40°C | |||
| Altitude | ≤2000m | |||
| Humidity | The relative humidity of the air is ≤50% at a maximum temperature of 40°C at the installation site, higher relative humidity may be permitted at lower temperatures, e.g. up to 90% at 20°C. Special measures should be taken for occasional condensation due to temperature changes. | |||
| Installation | Device Type, Rail Type | |||
| Conventional heating current Ith | 5A | |||
| Rated insulation voltage Ui | 400V | |||
| Rated impulse withstand voltage Uimp | 2.5KV | |||
| Ue/Ie | Rated Working Voltage Ue/Rated Working Current Ie:AC-15 Ue:AC250V,Ie:3A in each category of use. | |||
| Specification | HHS4P |
| Operating power | AC380V,AC220V,AC127V,AC110V,AC36V,AC24V, 50Hz;DC24V |
| Movement Forms | Power-on delay |
| Delay Range | 0.01s~0.99s;0.1s~9.9s;1s~99s;0.1s~99.9s;1s~999s;0.1m~9.9m;1m~99m;1h~99h; |
| Number of contacts | Delay 2 conversion; delay 1 conversion, instantaneous 1 conversion |
| Repetition error | Er<1% when the delay range is greater than 1s; Dr<50ms when the delay range is less than 1s. |
| Contact capacity | 3A AC250V (resistive) |
| Temperature range | -5°-40°C |
| Altitude | ≤2000m |
| Humidity | The relative humidity of the air is ≤50% at a maximum temperature of 40°C at the installation site, higher relative humidity may be permitted at lower temperatures, e.g. up to 90% at 20°C. Special measures should be taken for occasional condensation due to temperature changes. |
| Installation | Device Type, Rail Type |
| Conventional heating current Ith | 5A |
| Rated insulation voltage Ui | 400V |
| Rated impulse withstand voltage Uimp | 2.5KV |
| Ue/Ie | Rated Working Voltage Ue/Rated Working Current Ie:AC-15 Ue:AC250V,Ie:3A in each category of use. |
| Specification | HHS4PF |
| Operating power | AC380V,AC220V,AC127V,AC110V,AC36V,AC24V, 50Hz;DC24V |
| Movement Forms | Power Failure Delay |
| Delay Range | 0.1s~9.9s1s~99s1s~199s |
| Number of contacts | Delay 2 conversion |
| Repetition error | Er<5% when the delay range is greater than 1s. Dr<100ms when the delay range is less than 1s. |
| Contact capacity | 3A AC250V (resistive) |
| Temperature range | -5°-40°C |
| Altitude | ≤2000m |
| Humidity | The relative humidity of the air is ≤50% at a maximum temperature of 40°C at the installation site, higher relative humidity may be permitted at lower temperatures, e.g. up to 90% at 20°C. Special measures should be taken for occasional condensation due to temperature changes. |
| Installation | Device Type, Rail Type |
| Conventional heating current Ith | 5A |
| Rated insulation voltage Ui | 400V |
| Rated impulse withstand voltage Uimp | 2.5KV |
| Ue/Ie | Rated Working Voltage Ue/Rated Working Current Ie:AC-15 Ue:AC250V,Ie:3A in each category of use. |
Which timing modes are available?
The series covers power-on delay (HHS4), power-on delay with instantaneous contact (HHS4C), release delay (HHS4G) and power-off delay (HHS4PF). The digital HHS4P/PA types are also power-on delay.
What delay ranges can be ordered?
Analog types span 0.1 s to 3600 s in selectable ranges. Digital types extend from 0.01 s up to 99 hours.
Which supply voltages and contact ratings are supported?
Supply options are DC 24 V and AC 24, 36, 110, 127, 220 and 380 V at 50 Hz. Contacts are rated 3 A, AC 250 V (resistive).
How accurate is the timing?
Repeat error is below 1% for delays above 1 s on standard types. The power-off delay type is below 5%.
How is the relay mounted, and what conditions apply?
It mounts directly or on a 35 mm DIN rail. Ambient temperature is −5 to 40 °C and altitude ≤2000 m. The product page lists an MOQ of 60 pcs, while the category menu shows 200 pcs, so the quantity should be confirmed.
We has over 34 years of experience in this industry and has built a