MOQ : 60
Working power supply: DC24V; AC220V, AC380V
Working mode: reversible B counting, reversible C counting
Counting speed: high frequency 5000 times/second; low frequency 30 times/second
Counting range: 1-99999999
Value coefficient: 0.001-9.9999
Input signal: rotary encoder, meter wheel, PNP normally open photoelectric switch/proximity switch
Output mode: N, C, F, R, X standard
Power failure memory: 10 years
Contact form: a group of normally open and normally closed contacts
Dimensions: 96×48×114mm
Opening size: 92×45mm
Installation method: panel type
Remarks: High-speed counting: 5000 times/second, equipped with encoder and meter wheel, the motor can count up in forward rotation and count down in reverse rotation
| Specification | HHM2-H |
| Operating power | DC24V;AC220V、AC380V |
| Operating Mode | Reversible B Count, Reversible C Count |
| Counting speed | High frequency 5000 times/second; Low frequency 30 times/second |
| Counting Range | 1-99999999 |
| Coefficient of measurement | 0.001-9.9999 |
| Input signal | Rotary encoders, metre wheels, PNP normally open photoelectric switches / proximity switches |
| Blackout memory | 10 years |
| Output mode | N、C、F、R、X |
| Contact form | One set of normally open and normally closed contacts |
| Contact capacity | 3A AC250V (resistive) |
| Temperature range | -5°-40°C |
| Dimensions | 96×48×114mm |
| Opening dimensions | 92×45mm |
| Installation | panel mounted |
Which input devices can connect to the HHM2-H?
Rotary encoders, meter wheels, and PNP normally-open photoelectric or proximity switches. Reversible counting allows up and down counting with forward and reverse motor rotation.
What counting speed is supported?
High-frequency counting reaches 5000 counts per second, and low-frequency counting is 30 counts per second.
Does the count survive a power failure?
Yes. The blackout memory holds data for 10 years, so production totals are preserved after outages.
What is the value coefficient used for?
The coefficient is adjustable from 0.001 to 9.9999. It converts pulses into practical units such as length with a meter wheel. The counting range is 1–99999999.
What output modes and panel size are available?
Output modes are N, C, F, R and X, with one NO and one NC contact (3 A, AC 250 V). It is panel-mounted at 96×48×114 mm with a 92×45 mm cut-out. MOQ is 60 pcs.