MOQ : 12
Voltaje de control: 3-32VDC
Corriente de control: 5-25MA
Voltaje de carga: 120: 60-1200VAC
Corriente de carga: 500A, 600A, 800A, 1000A
Caída de voltaje en el estado: AC < 1.6VAC
Tiempo de encendido: Ac≤10ms
Corriente de fuga fuera del estado AC≤10MA
Voltaje de resistencia dieléctrica: ≥2500 VAC
Temperatura ambiente: -30 ~ 80 ℃
Dimensiones: 500-600A: 115 × 53 × 60 mm
800A: 125 × 63 × 70 mm
1000A: 149 × 66 × 76 mm
Formulario de instalación: instalación de pernos
Descripción: Las cargas superiores a 5A deben estar equipadas con un radiador
Cargas por encima de 80A deben estar equipadas con enfriamiento forzado de ventilador o enfriamiento de agua
| Serie HHG1K | |
| Modelo | HHG1K-1/032F-120 (SSR-DA) |
| Voltaje de control | 3-32VDC |
| Corriente de control | 5-25MA |
| Voltaje de carga | 120: 60-1200VAC |
| Corriente de carga | 500A, 600A, 800A, 1000A |
| Caída de voltaje en el estado | AC ≤ 1.6VAC |
| Tiempo de apagado | Ac≤ 10 ms |
| Corriente de fuga fuera del estado | AC ≤ 10 mA |
| Resistencia dieléctrica | ≥ 2500 VAC |
| Temperatura ambiente. | -30 ~ 80 ° C |
| Dimensión | 500-600A: 115 × 53 × 60 mm 800A: 125 × 63 × 70 mm 1000A: 149 × 66 × 76 mm |
| Formulario de instalación | Instalación de pernos |
| Instrucción | Se debe instalar un radiador para cargas superiores a 5a; Se debe agregar un ventilador de enfriamiento fuerte o enfriamiento de agua para cargas superiores a 80A |
Q1. How much current margin is recommended when selecting a 500–1000A SSR?
Do not select at the load current. Add margin for inrush, ambient temperature and heat-sink quality, and a larger margin still for inductive loads. Resistive heaters need less margin than transformers or motors. Send the load, supply voltage and cabinet temperature, and our engineers will suggest a model.
Q2. Does a 1000A solid state relay need short-circuit protection?
Yes. An SSR is not short-circuit proof, and a fault current can destroy the output stage before an ordinary breaker trips. Use a fast-acting semiconductor fuse coordinated with the relay’s I²t withstand. Ask us for the I²t data for the chosen model when requesting a quote.
Q3. With ≤10mA off-state leakage, is the load truly de-energized?
No. An SSR is not an isolating device. Leakage of up to 10mA can keep small loads faintly energized, and the output remains connected to the line. For maintenance, use an upstream disconnect or contactor as well. This also matters for loads sensitive to small leakage currents.
Q4. Can the HHG1K be used on three-phase 380V, 480V or 690V systems?
The load voltage range is 60–1200VAC, which covers common three-phase supplies with headroom for transients. A three-phase heater bank typically uses one relay per controlled phase, depending on wiring. Tell us the supply voltage and connection, star or delta, and we will confirm the arrangement.
Q5. How is the correct HHG1K rating determined for heating control cabinets?
Send the heater power in kW, supply voltage, number of phases and cooling method. We will calculate the load current and suggest 500A, 600A, 800A or 1000A. The MOQ is 12 pcs, so single cabinets and project batches are both possible.