MOQ : 240
Le DZ47-63 is our high-demand bulk circuit breakers solution, engineered for large-scale residential project supply. This 63A frame MCB provides essential overload and short-circuit protection for mass housing developments and residential tower blocks. As a leading miniature circuit breaker manufacturer, we ensure that every unit meets the GB/T 10963.1 standard, offering project contractors a reliable, cost-effective component for high-volume consumer unit assembly. Request a quote Now!
Designed for space-efficient integration, the Dz47le-32 is a preferred low voltage switchgear component for commercial equipment manufacturers. With a compact 32A frame, it is ideally suited for bulk procurement by commercial plaza developers and office complex fit-out contractors. This series ensures precision protection for modular commercial circuits, including centralized LED lighting systems and workstation power distribution, where standardized quality is paramount for large-scale tenders.
Le Dz47le-63 series is built for the rigorous demands of high-rise electrical equipment procurement. Featuring a robust 63A frame, it addresses the heavy-duty distribution needs of vertical infrastructure, such as hotel elevator systems, central HVAC networks, and high-rise pump rooms. We offer these units with customizable pole configurations to meet specific engineering blueprints, providing the reliability required for multi-story safety certifications and large-scale utility tenders.
Le DZ47-63H is our premium variant for those seeking a reliable industrial circuit breaker manufacturer for heavy-duty applications. The “H” design code signifies an upgraded build for industrial workshops and factory-wide power grids. This series is optimized for bulk procurement by industrial automation integrators and heavy machinery manufacturers who require stable 50Hz performance for CNC machine tool arrays and automated assembly lines in high-frequency operational environments.
Tension de travail nominale: AC230V / 400V
Fréquence nominale: 50Hz
Évalué le courant de travail: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Nombre de poteaux: 1p, 2p, 3p, 4p
Formulaire de déclenchement instantané: Type C (5 ~ 10 pouces), type D (10 ~ 20 pouces)
Type de protection: protection de la distribution, protection du moteur
Capacité de rupture court-circuit (USI): 4KA
Dimensions de l'apparence et de l'installation: voir le manuel d'instructions ou le manuel de sélection
Méthode d'installation: Installation de rail standard de 35 mm
Norme de mise en œuvre du produit: GB / T 10963.1
| Spécification | DZ47-63 |
| Tension de travail | AC230V / 400V |
| Fréquence nominale | 50Hz |
| Courant de fonctionnement nominal | 1A 、 2A 、 3A 、 4A 、 6A 、 10A 、 16A 、 20A 、 25A 、 32A 、 40A 、 50A 、 63A |
| Pôle | 1p 、 2p 、 3p 、 4p |
| Formulaire de libération instantanée | CTYPE (5 ~ 10 pouces) 、 D Type (10 ~ 20in) |
| Type de protection | Protection de la distribution, protection du moteur |
| Courant d'action de fuite noté (i △ n) | 30 mA 、 50mA 、 100mA |
| Capacité de rupture court-circuit (USI) | 4ka |
| Dimensions | Trouver des instructions de fonctionnement ou un manuel de sélection |
| Installation | Montage des rails standard de 35 mm |
| Normes de mise en œuvre du produit | GB / T 10963.1 |
Tension de travail nominale: AC230V / 400V
Fréquence nominale: 50Hz
Courant de travail nominal: 6A, 10A, 16A, 20A, 25A, 32A
Nombre de pôles: 1p + n, 2p, 3p, 3p + n, 4p
Formulaire de déclenchement instantané: Type B (3 ~ 5 po), type C (5 ~ 10 po), type D (10 ~ 20 pouces)
Type de protection: protection de la distribution, protection du moteur
Courant de fonctionnement des fuites nominales (i △ n): 30mA, 50mA, 100mA
Capacité de rupture court-circuit (USI): 4KA
Dimensions de l'apparence et de l'installation: voir le manuel d'instructions ou le manuel de sélection
Méthode d'installation: Installation de rail standard de 35 mm
Norme de mise en œuvre du produit: GB / T 16917.1
| Spécification | Dz47le-32 |
| Tension de travail | AC230V / 400V |
| Fréquence nominale | 50Hz |
| Courant de fonctionnement nominal | 6A 、 10A 、 16A 、 20A 、 25A 、 32A |
| Pôle | 1p + n 、 2p 、 3p 、 3p + n 、 4p |
| Formulaire de libération instantanée | B type (3 ~ 5in) 、 C type (5 ~ 10 pouces) 、 DTYPE (10 ~ 20 pouces) |
| Type de protection | Protection de la distribution, protection du moteur |
| Courant d'action de fuite noté (i △ n) | 30 mA 、 50mA 、 100mA |
| Capacité de rupture court-circuit (USI) | 4ka |
| Dimensions | Trouver des instructions de fonctionnement ou un manuel de sélection |
| Installation | Montage des rails standard de 35 mm |
| Normes de mise en œuvre du produit | GB / T 16917.1 |
Tension de travail nominale: AC230V / 400V
Fréquence nominale: 50Hz
Courant de travail nominal: 40A, 50A, 63A
Nombre de pôles: 1p + n, 2p, 3p, 3p + n, 4p
Formulaire de déclenchement instantané: Type B (3 ~ 5 po), type C (5 ~ 10 po), type D (10 ~ 20 pouces)
Type de protection: protection de la distribution, protection du moteur
Courant de fonctionnement des fuites nominales (i △ n): 30mA, 50mA, 100mA
Capacité de rupture court-circuit (USI): 4KA
Dimensions de l'apparence et de l'installation: voir le manuel d'instructions ou le manuel de sélection
Méthode d'installation: Installation de rail standard de 35 mm
Norme de mise en œuvre du produit: GB / T 16917.1
| Spécification | Dz47le-63 |
| Tension de travail | AC230V / 400V |
| Fréquence nominale | 50Hz |
| Courant de fonctionnement nominal | 40A 、 50A 、 63A |
| Pôle | 1p + n 、 2p 、 3p 、 3p + n 、 4p |
| Formulaire de libération instantanée | B type (3 ~ 5in) 、 C type (5 ~ 10 pouces) 、 DTYPE (10 ~ 20 pouces) |
| Type de protection | Protection de la distribution, protection du moteur |
| Courant d'action de fuite noté (i △ n) | 30 mA 、 50mA 、 100mA |
| Capacité de rupture court-circuit (USI) | 4ka |
| Dimensions | Trouver des instructions de fonctionnement ou un manuel de sélection |
| Installation | Montage des rails standard de 35 mm |
| Normes de mise en œuvre du produit | GB / T 16917.1 |
Tension de travail nominale: AC230V / 400V
Fréquence nominale: 50Hz
Courant de fonctionnement nominal : 1A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Nombre de poteaux: 1p, 2p, 3p, 4p
Forme de déclenchement instantané : Type C (5~10In), Type D (10~20In)
Type de protection: protection de la distribution, protection du moteur
Coupure nominale en court-circuit
Capacité : kA
Dimensions hors tout et de montage : reportez-vous au manuel d'utilisation ou au guide de sélection
Norme d'exécution du produit : GB/T 10963.1
| Disjoncteur miniature DZ47-63H | |
| Tension de fonctionnement nominale | AC230V / 400V |
| Fréquence nominale | 50Hz |
| Courant de fonctionnement nominal | 1A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A |
| Nombre de pôles | 1p, 2p, 3p, 4p |
| Type de déclenchement instantané | Type C (5 ~ 10 pouces), type D (10 ~ 20 pouces) |
| Type de protection | Protection de distribution, protection de moteur |
| Coupure nominale en court-circuit Capacité | 6ka |
| Globalement et montage Dimensions | Reportez-vous au manuel d'utilisation ou au guide de sélection |
| Norme d'exécution du produit | GB / T 10963.1 |
Q1: How do I accurately choose the MCB rating for my industrial circuit?
To choose the correct MCB rating, ensure the breaker’s rated current is higher than your equipment’s full load but lower than the cable’s maximum capacity. This prevents nuisance tripping while safeguarding your bulk electrical supplies and infrastructure.
Q2: When should I specify a Type D curve instead of Type C for a business?
Standard commercial lighting usually requires Type C, but MCBs for industrial applications with high-surge motors or transformers need Type D to handle initial inrush currents. Selecting the wrong curve can lead to frequent downtime in large-scale production environments.
Q3: Why is breaking capacity a critical factor in bulk MCB procurement?
Le breaking capacity of an MCB determines the maximum fault current it can safely interrupt without failing. For high-rise and industrial projects, always verify the kA rating matches the potential short-circuit levels at the installation point to ensure long-term safety.
Q4: Should my project use a single-pole or 3-phase MCB for business operations?
Single-pole breakers are ideal for individual office branch circuits, whereas a 3 phase MCB for business is necessary for heavy machinery and commercial HVAC systems requiring balanced power distribution. Matching the pole count to your engineering blueprints is essential for system stability.
Nous avons fini 34 années d'expérience dans cette industrie et a construit un
Réputation de fournir des produits et services de qualité à des prix compétitifs.