Measuring signal: AC current (AC0~5A); AC voltage (AC0~500V)
Other specifications can be customized
Measurement error: ≤0.5 level
Display mode: Manually switch to display the measured primary power or the output power
Display range: Primary power 0~9999 can be freely set
Transmitter output: DC0~10mA/0~20mA/4~20mA (freely set)
Load impedance: ≤350Ω
Working power supply: AC220V, AC380V
Dimensions: 79×50×105mm
Installation method: Standard DIN rail installation, fixed installation
Typical applications: Used for transmission, isolation and measurement of large current and high voltage in explosion-proof control boxes, distribution cabinets, transformer boxes and other equipment
| PAS Series | ||
| Model | PAS-A | PAS-V |
| Measurement signal | AC current (AC0~5A) | AC voltage (AC0~500V) |
| Measurement error | ≤ 0.5 class | |
| Display mode | It can be manually switched to display the measured primary electric quantity or transmitting output electric quantity | |
| Display range | Primary electric quantity 0~9999 settable | |
| Transmission output | DC0~10mA/0~20mA, 4~20mA (settable) | |
| Load impedance | ≤ 350Ω | |
| Supply voltage | AC220V or AC380V | |
| Dimension | 79×50×105mm | |
| Installation method | Standard DIN rail installation, fixed installation | |
| Typical application | Used for isolation and measurement of high current and high voltage transmission in explosion-proof control boxes, distribution | |
What is the difference between PAS-A and PAS-V?
PAS-A measures AC current of 0–5 A, and PAS-V measures AC voltage of 0–500 V. The two share the same accuracy, output and housing. The measured quantity decides the model.
Can the display show primary-side values for CT/PT-based systems?
Yes. The display range for primary quantity is freely settable from 0 to 9999, and the display can be switched between the primary value and the output value. This suits 0–5 A secondary measurement with current transformers.
What output signals and load limits apply?
Output is selectable among 0–10 mA, 0–20 mA and 4–20 mA, with a load impedance of ≤350 Ω. These signals are compatible with common PLC and DCS analog inputs.
What measurement accuracy is provided?
Measurement error is within 0.5 class. This suits monitoring, isolation and signal transmission in power distribution systems.
How is the transmitter installed, and can specifications be customized?
It mounts on a standard DIN rail or is fixed in place, at 79×50×105 mm, with a 220 VAC or 380 VAC supply. Typical locations are explosion-proof control boxes, distribution cabinets and transformer boxes. Other specifications can be customized, and MOQ is 50 pcs.