<뒤로

솔리드 스테이트 릴레이 HHG62 시리즈

MOQ : 300

FAQ

Q1. What is the RX78624 socket, and is it required?
The page lists RX78624 as the adapter socket for this series. It supports dual in-line plug-in and DIN-rail installation. For rail mounting, send the layout and we will confirm the socket and quantity.

Q2. When should the HHG63 be chosen instead of the HHG62?
HHG62 covers 1–4A in a 29×12.6×28mm body. If 5A (aluminum shell), the 10A DC model, or the UL and CCC certification listed on the HHG63 page is needed, use the HHG63. Send the load current and certification requirements.

Q3. Can a 3.3V microcontroller GPIO drive the HHG62?
The control range is 3–32VDC at 5–25mA. A 3.3V GPIO sits at the low end of the voltage range and most pins cannot supply that current. Use a transistor or driver stage. Send the control circuit and we can check the drive design.

Q4. Which HHG62 models should distributors stock first?
The series has -22 (24–240VAC), -38 (24–440VAC) and -20 (12–200VDC) output versions, in ratings from 1A to 4A. Send the target market and customer types, and we will suggest a starting stock mix. The MOQ is 300 pcs.

Q5. How hot does a 4A relay get, and how should units be spaced?
At 4A the on-state drop produces roughly 5–6W per relay. Install beside a ventilated heat-dissipation window, leave gaps between units and stay within -30℃ to 80℃. Send the panel layout and duty cycle and we will advise on spacing and derating.

관련 제품

우리는 끝났습니다 34 이 산업에서 수년간의 경험을 쌓았으며
경쟁력있는 가격으로 양질의 제품 및 서비스 제공에 대한 명성.

관련 뉴스

타임 스위치는 무엇이며 어떻게 작동합니까?
릴레이 대 컨택 터 : 8 가지 주요 차이점을 알아야합니다
회로 차단기 VS 모터 회로 보호기: 6가지 주요 차이점
타임 릴레이 배선 : 단계별 가이드
ko_KR

당신의 말씀 해주세요 요구 사항 질문 필요합니다 아이디어 계획



Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.