MOQ : 300
Kontrol Voltajı: 3-32VDC
Kontrol Akımı: 5-25mma
Yük Voltajı: 22: 24-240VAC, 38: 24-440VAC
Yük akımı: 1a, 2a, 3a, 4a
Durum Üstü Voltaj Düşüşü: ACY1.6VAC
Kontrol Koruması: AC≤10ms
Durum dışı sızıntı akımı: AC≤10ms
Dielektrik dayanma voltajı: ≥ 1500vac
Ortam sıcaklığı: -30 ~ 80 ℃
Boyutlar: 29 × 12.6 × 28mm
Kurulum Formu: Dip, Rail Ray Kurulumu
Açıklama: İyi havalandırma ile bir ısı dağılma penceresinin yanına yükleyin
Not: Adaptör Soketi RX78624
| HHG62 Serisi | ||
| Model | HHG62-1/032F-22 (SSR-DA) HHG62-1/032F-38 (SSR-DA) | HHG62-0/032F-20 (SSR-DD) |
| Kontrol voltajı | 3-32VDC | |
| Kontrol akımı | 5-25mma | |
| Yük voltajı | 22: 24-240VAC 38: 24-440VAC 20: 12-200VDC | |
| Yük akımı | 1a, 2a, 3a, 4a | |
| Durum üzerindeki voltaj düşüşü | AC ≤ 1.2VAC | |
| ON-OFF Saati | AC≤ 5ms | |
| Devlet dışı sızıntı akımı | AC ≤ 5mA | |
| Dielektrik mukavemet | ≥ 1500VAC | |
| Ortam sıcaklığı. | -30 ~ 80 ° C | |
| Boyut | 29 × 12.6 × 28mm | |
| Kurulum formu | Çift Çizgi Doğrudan Eklenti ve DIN Ray kurulumu | |
| Talimat | İyi havalandırılmış ısı yayma penceresinin yanına monte edilmiştir | |
Q1. What is the RX78624 socket, and is it required?
The page lists RX78624 as the adapter socket for this series. It supports dual in-line plug-in and DIN-rail installation. For rail mounting, send the layout and we will confirm the socket and quantity.
Q2. When should the HHG63 be chosen instead of the HHG62?
HHG62 covers 1–4A in a 29×12.6×28mm body. If 5A (aluminum shell), the 10A DC model, or the UL and CCC certification listed on the HHG63 page is needed, use the HHG63. Send the load current and certification requirements.
Q3. Can a 3.3V microcontroller GPIO drive the HHG62?
The control range is 3–32VDC at 5–25mA. A 3.3V GPIO sits at the low end of the voltage range and most pins cannot supply that current. Use a transistor or driver stage. Send the control circuit and we can check the drive design.
Q4. Which HHG62 models should distributors stock first?
The series has -22 (24–240VAC), -38 (24–440VAC) and -20 (12–200VDC) output versions, in ratings from 1A to 4A. Send the target market and customer types, and we will suggest a starting stock mix. The MOQ is 300 pcs.
Q5. How hot does a 4A relay get, and how should units be spaced?
At 4A the on-state drop produces roughly 5–6W per relay. Install beside a ventilated heat-dissipation window, leave gaps between units and stay within -30℃ to 80℃. Send the panel layout and duty cycle and we will advise on spacing and derating.
Bittik 34 bu sektörde yılların deneyimini oluşturdu ve bir