MOQ : 100
Non-tripping impulse current le (8/20μs): 10kA, 20kA, 40kA, 60kA, 80kA, 100kA, 120kA, 160kA
Non-tripping impulse current le (10/350μs): 15kA, 25kA
Rated working voltage Ue: 230/400VAC
Current trip value li: 3±1A
Maximum short-circuit breaking capacity Icn: 15kA, 25kA, 35kA, 50kA, 65kA
Mechanical life: 10,000 times
Electrical life: 4,000 times
Normal working environment: -5~+40℃
Installation method: 35mm standard rail
Number of poles: 1P, 2P, 3P, 4P
Appearance and installation dimensions (mm) ≤ 80kA: 90×18×74 (1P), 90×36×74(2P), 90×54×74(3P), 90×72×74(4P), ≥ 100kA: 90×36×74(1P), 90×72×74(2P), 90×108×74(3P), 90×144×74(4P)
Non-tripping impulse current le (8/20μs): 10kA, 20kA, 40kA, 60kA, 80kA, 100kA, 120kA, 160kA
Non-tripping impulse current le (10/350μs): 15kA, 25kA
Rated working voltage Ue: 230/400VAC
Current trip value li: 3±1A
Maximum short-circuit breaking capacity Icn: 15kA, 25kA, 35kA, 50kA, 65kA
Mechanical life: 10,000 times
Electrical life: 4,000 times
Normal working environment: -5~+40℃
Installation method: 35mm standard rail
Number of poles: 1P, 2P, 3P, 4P
Appearance and installation dimensions (mm) ≤ 80kA: 90×18×74 (1P), 90×36×74(2P), 90×54×74(3P), 90×72×74(4P), ≥ 100kA: 90×36×74(1P), 90×72×74(2P), 90×108×74(3P), 90×144×74(4P)
| Specification | XLSCB Series |
| Rated operating voltage Ue | 230/400VAC |
| Current tripping value lo | 3±1A |
| Power frequency short-circuit current breaking time Tos | ≤ 40ms |
| Power frequency load current breaking time To | ≤ 50ms |
| Mechanical life | 4000 |
| Electrical life | 4000 |
| Temperature | -25~+60ºC |
| Installation | 35mm Standard Rail |
| Phase | 2P 3P 4P |
| Dimensions | 85×36×73.5(2P) 85×72×73.5(3P,4P) |
| Specification | XLSCB2 |
| Non-tripping impulse current le (8/20μs) | 10kA, 20kA, 40kA, 60kA, 80kA, 100kA, 120kA, 160kA |
| Non-tripping impulse current le (10/350μs) | 15kA, 25kA |
| Rated working voltage Ue | 230/400VAC |
| Current trip value li | 3±1A |
| Maximum short-circuit breaking capacity Icn | 15kA, 25kA, 35kA, 50kA, 65kA |
| Mechanical life | 10,000 times |
| Electrical life | 4,000 times |
| Normal working environment | -5~+40℃ |
| Installation method | 35mm standard rail |
| Number of poles | 1P, 2P, 3P, 4P |
| Appearance and installation dimensions (mm) | ≤ 80kA: 90×18×74 (1P), 90×36×74(2P), 90×54×74(3P), 90×72×74(4P), ≥ 100kA: 90×36×74(1P), 90×72×74(2P), 90×108×74(3P), 90×144×74(4P) |
We has over 34 years of experience in this industry and has built a
reputation for providing quality products and services at competitive prices.