MOQ : 144
The DZ47LE series residual current circuit breaker is applicable to circuits with a rated voltage of 230V or 400V, a frequency of 50Hz, and a rated current of up to 63A and below. It is used for personal electric shock protection, and simultaneously provides protection against leakage, overload and open circuit of electrical circuits and equipment in residential and similar buildings.
This product complies with the standard GB/T 16917.1.
The DZ47LE series residual current circuit breaker is applicable to circuits with a rated voltage of 230V or 400V, a frequency of 50Hz, and a rated current of up to 63A and below. It is used for personal electric shock protection, and simultaneously provides protection against leakage, overload and open circuit of electrical circuits and equipment in residential and similar buildings.
This product complies with the standard GB/T 16917.1.
| DZ47LE-32 Miniature Residual Current Circuit Breaker | |
| Rated Operating Voltage | 1P+N/2P AC230V, 3P/3P+N/4P AC400V |
| Rated Frequency | 50Hz |
| Rated Operating Current | 6A, 10A, 16A, 20A, 25A, 32A |
| Number of Poles | 1P+N, 2P, 3P, 3P+N, 4P |
| Instantaneous Trip Type | Type C, Type D |
| Protection Type | Distribution Protection, Motor Protection |
| Rated Residual Operating Current | 30mA, 50mA |
| Rated Short-circuit Breaking Capacity | 6kA |
| Overall and Mounting Dimensions | Refer to the User Manual |
| Product Execution Standard | GB/T 16917.1 |
| DZ47LE-63L Miniature Residual Current Circuit Breaker | |
| Rated Operating Voltage | AC230V/400V |
| Rated Frequency | 50Hz |
| Rated Operating Current | 40A, 50A, 63A |
| Number of Poles | 1P+N, 2P, 3P, 3P+N, 4P |
| Instantaneous Trip Type | Type C (5~10In), Type D (10~20In) |
| Protection Type | Distribution Protection, Motor Protection |
| Rated Residual Operating Current | 30mA, 50mA |
| Rated Short-circuit Breaking Capacity | 6kA |
| Overall and Mounting Dimensions | Refer to the User Manual or Selection Guide |
| Product Execution Standard | GB/T 16917.1 |
Product Overview
The DZ47LE series residual current circuit breaker is applicable to circuits with a rated voltage of 230V or 400V, a frequency of 50Hz, and a rated current of up to 63A and below. It is used for personal electric shock protection, and simultaneously provides protection against leakage, overload and open circuit of electrical circuits and equipment in residential and similar buildings.
This product complies with the standard GB/T 16917.1.
We has over 34 years of experience in this industry and has built a
reputation for providing quality products and services at competitive prices.