Control mode: 4-20mA, 0-5V, 0-10V three modes are optional
Output mode: phase output, phase shift range 0-150°
Load voltage: three-phase 380VAC (three-phase three-wire)
Load current: 125, 150, 200A
Protection function: fast fuse
Alarm function: phase failure, overtemperature, relay output (1A/250VAC)
Dielectric withstand voltage: ≥2000VAC
Display function: LED panel displays SCR output percentage and working status indication
Installation method: bolt installation
Used load: fixed impedance heating wire, IR far infrared, UV lamp, etc.
Dimensions: 285×148×210mm
Cooling method: forced air cooling
Control mode: 4-20mA, 0-5V, 0-10V three modes are optional
Output mode: phase output, phase shift range 0-150°
Load voltage: three-phase 380VAC (three-phase three-wire)
Load current: 40A
Protection function: fast fuse
Alarm function: phase failure, overtemperature, relay output (1A/250VAC)
Dielectric withstand voltage: ≥2000VAC
Display function: LED panel displays SCR output percentage and working status indication
Installation method: bolt installation
Used load: fixed impedance heating wire, IR far infrared, UV lamp, etc.
Dimensions: 150×130×175mm
Cooling method: forced air cooling
Control mode: 4-20mA, 0-5V, 0-10V three modes are optional
Output mode: phase output, phase shift range 0-150°
Load voltage: three-phase 380VAC (three-phase three-wire)
Load current: 75, 100A
Protection function: fast fuse
Alarm function: phase failure, overtemperature, relay output (1A/250VAC)
Dielectric withstand voltage: ≥2000VAC
Display function: LED panel displays SCR output percentage and working status indication
Installation method: bolt installation
Used load: fixed impedance heating wire, IR far infrared, UV lamp, etc.
Dimensions: 218×130×175mm
Cooling method: forced air cooling
Control mode: 4-20mA, 0-5V, 0-10V three modes are optional
Output mode: phase output, phase shift range 0-150°
Load voltage: three-phase 380VAC (three-phase three-wire)
Load current: 25A
Protection function: fast fuse
Alarm function: phase failure, overtemperature, relay output (1A/250VAC)
Dielectric withstand voltage: ≥2000VAC
Display function: LED panel displays SCR output percentage and working status indication
Installation method: bolt installation
Used load: fixed impedance heating wire, IR far infrared, UV lamp, etc.
Dimensions: 150×130×175mm
Cooling method: natural cooling
HHT4 Series | |
Model | HHT4-4/38 125P |
Control mode | Three options: 4-20mA, 0-5V, 0-10V |
Output method | Phase output, phase shift range 0-150° |
Load voltage | 3-phase 380VAC (3-phase 3-wire) |
Load current | 125A |
Protection function | Quick fuse |
Alarm function | Phase failure, overtemp, relay output (1A/250VAC |
Dielectric strength | ≥2000VAC |
Display function | LED panel displays SCR output percentage and wor |
Installation method | Bolt installation |
Use load | Fixed impedance heating wire, IR far infrared, UV lamp tube, etc |
Dimension | 285×148×210mm |
Cooling method | Forced air cooling |
HHT4 Series | |
Model | HHT4-4/38 40P |
Control mode | Three options: 4-20mA, 0-5V, 0-10V |
Output method | Phase output, phase shift range 0-150° |
Load voltage | 3-phase 380VAC (3-phase 3-wire) |
Load current | 40A |
Protection function | Quick fuse |
Alarm function | Phase failure, overtemp, relay output (1A/250VAC |
Dielectric strength | ≥2000VAC |
Display function | LED panel displays SCR output percentage and wor |
Installation method | Bolt installation |
Use load | Fixed impedance heating wire, IR far infrared, UV lamp tube, etc |
Dimension | 150×130×175mm |
Cooling method | Forced air cooling |
HHT4 Series | |
Model | HHT4-4/38 75P |
Control mode | Three options: 4-20mA, 0-5V, 0-10V |
Output method | Phase output, phase shift range 0-150° |
Load voltage | 3-phase 380VAC (3-phase 3-wire) |
Load current | 75A |
Protection function | Quick fuse |
Alarm function | Phase failure, overtemp, relay output (1A/250VAC |
Dielectric strength | ≥2000VAC |
Display function | LED panel displays SCR output percentage and wor |
Installation method | Bolt installation |
Use load | Fixed impedance heating wire, IR far infrared, UV lamp tube, etc |
Dimension | 218×130×175mm |
Cooling method | Forced air cooling |
HHT4 Series | |
Model | HHT4-4/38 25P |
Control mode | Three options: 4-20mA, 0-5V, 0-10V |
Output method | Phase output, phase shift range 0-150° |
Load voltage | 3-phase 380VAC (3-phase 3-wire) |
Load current | 25A |
Protection function | Quick fuse |
Alarm function | Phase failure, overtemp, relay output (1A/250VAC |
Dielectric strength | ≥2000VAC |
Display function | LED panel displays SCR output percentage and wor |
Installation method | Bolt installation |
Use load | Fixed impedance heating wire, IR far infrared, UV lamp tube, etc |
Dimension | 150×130×175mm |
Cooling method | Natural cooling |
We has over 34 years of experience in this industry and has built a
reputation for providing quality products and services at competitive prices.