Input voltage: 3PH AC380V 50/60Hz
Output voltage: 3PH AC0-380V 0-500Hz
Rated power: 0.75kW 1.5kW 2.2kW
Rated current: 2.1A 3.8A 5.1A
Control mode: V/F control, vector control
Overload capacity: 150% rated current 60s; 190% rated current 1.5s
Protection function: overvoltage, overcurrent, undervoltage, overheating, short circuit
Protection level: IP20
Dimensions: 170.2×84.6×138.1mm
Installation dimensions: 67.3×157.5 and 35mm rail installation
Cooling method: forced air cooling
Place of use: Altitude ≤1000 meters, derating is required if the altitude exceeds the limit, no corrosive gases or liquids in the room
Input voltage: 3PH AC380V 50/60Hz
Output voltage: 3PH AC0-380V 0-500Hz
Rated power: 3.7kW 5.5kW
Rated current: 9A 13A
Control mode: V/F control, vector control
Overload capacity: 150% rated current 60s; 190% rated current 1.5s
Protection function: overvoltage, overcurrent, undervoltage, overheating, short circuit
Protection level: IP20
Dimensions: 194×97×153.3mm
Installation dimensions: 85×184 and 35mm rail installation
Cooling method: forced air cooling
Place of use: Altitude ≤1000 meters, derating is required if the altitude exceeds the limit, no corrosive gases or liquids in the room
Input voltage: 1PH AC220V 50/60Hz
Output voltage: 3PH AC0-220V 0-500Hz
Rated power: 0.4Kw, 0.75Kw, 1.5Kw
Rated current: 2.3A, 4A, 7A
Control mode: V/F control, vector control
Overload capacity: 150% rated current 60s; 190% rated current 1.5s
Protection function: overvoltage, overcurrent, undervoltage, overheating, short circuit
Protection level: IP20
Dimensions: 165×78×116mm
Installation dimensions: 65×155 and 35mm rail installation
Cooling method: forced air cooling
Place of use: Altitude ≤1000 meters, derating is required if the altitude exceeds the limit, no corrosive gases or liquids in the room
Input voltage: 3PH AC380V 50/60Hz
Output voltage: 3PH AC0-220V 0-500Hz
Rated power: 0.75Kw, 1.5Kw, 2.2Kw
Rated current: 2.1A, 3.8A, 5.1A
Control mode: V/F control, vector control
Overload capacity: 150% rated current 60s; 190% rated current 1.5s
Protection function: overvoltage, overcurrent, undervoltage, overheating, short circuit
Protection level: IP20
Dimensions: 165×78×116mm
Installation dimensions: 65×155 and 35mm rail installation
Cooling method: forced air cooling
Place of use: Altitude ≤1000 meters, derated for use above altitude No corrosive gases, liquids, etc. in the room
Speicification | XLP530 Series |
Input Voltage | 1PH / 3PH AC380V 50/60Hz |
Output Voltage | 1PN / 3PH AC0-380V 0-500Hz |
Rating | 0.75kW 1.5kW 2.2kW |
Rated current | 2.1A 3.8A 5.1A |
Control Mode | V/F control, vector control |
Overload capacity | 150 per cent of rated current 60s; 190 per cent of rated current 1.5s |
Protective function | Over-voltage, over-current, under-voltage, overheat, short circuit |
Protection class | IP20 |
We has over 34 years of experience in this industry and has built a