HHN-RA4
Model HHN-RA4
Contact resistance 100mΩ or less
Operation time (effectiveness) 10ms or less (approx. 3ms)
Reset time (effectiveness) 15ms or less (approx. 4ms)
Insulation resistance 100mΩ or above (DC500V megohmmeter)
Shock Duration 1000m/s²
Misoperation 100m/s²
Mechanical life ≥ 500000 times (switching frequency 18000 times/h)
Electrical life ≥ 100000 times (rated load, switching frequency 1800 times/h)

 

HHN-RA5
Model HHN-RA5
Contact 1 CO
Switching current 6A 250V AC
Minimum load 100mA / 12V
Switching Capacity DC-1 30V: 180W; AC-1 230V: 1500VA; DC-15 230V: 300VA
Surge current 15A / 2.5ms
Mechanical life 10×10⁶
Electrical life 3×10⁴
Operating voltage 0.8~1.25Un
Delay/release time 7 / 15ms

 

 

HHN-RA67
Model HHN-RA67
Rated voltage 24VDC (with permissible variation range of 80%~110% )
Single circuit operating power consumption Approx. 216mW
Polarity requirement for wiring No polarity requirement
Number of control channels 4, 8, 12, 16
Relay model 41F
Contact type RA6: 1H; RA7: 1Z
Rated voltage 250VAC/30VDC
Rated current 6A/circuit
Operation time <6ms
Release time <3.0ms

 

HHN-RA123 series
Model HHN-RA1 HHN-RA2 HHN-RA3
Rated voltage DC24V
Rated current 7.5mA, 8.3mA
Operating voltage ≥75% (normal temperature environment)
Release voltage ≤ 5% (normal temperature environment)
Operation time 20ms or less
Release time 10ms or less
Contact resistance 30mΩ or less (DC6V 1A)      100mΩ or less(DC6V 1A)
nsulation impedance 1000mΩ(500VDC)

 