Specification | HHS18 | HHS18R | HHS18F |
Operating power | DC24V;AC24V,AC36V,AC110V,AC220V,AC380V 50Hz | ||
Working Mode | Power-on delay eight modes | Cyclic delay | Power failure delay |
Delay range | 0.1s-120h | 0.1s-100h | 0.1s~1s;0.2s~2s;0.5s~5s;1s~10s3s~30s;6s~60s;12s~120s;18s~180s |
Repetition error | Er≤1% for delay range >1s; Er<50ms for delay range <1s | Er≤5% for delay range >1s; Er<100ms for delay range <1s | |
Contact form | HHS18, HHS18R: two sets of time-delay changeover contacts HHS18-C, HHS18R-C: one set of time-delay, one set of instantaneous | two sets of time-delay changeover contacts | |
Contact capacity | 1A AC240V (resistive) | 3A AC250V (resistive) | 1A AC250V (resistive) |
Ue/Ui | Rated working voltage Ue/rated working current Ie:AC-15 Ue:AC250V,Ie:3A for each category of use. | ||
Temperature range | -5°-40°C | ||
Altitude | ≤2000m | ||
Ith | 5A | ||
Ui | 400V | ||
Uimp | 2.5KV | ||
Installation | Mounted, Rail Mounted | ||
Humidity | The relative humidity of the air shall be ≤50 per cent at a maximum temperature of 40°C at the place of installation, and higher relative humidity may be permitted at lower temperatures, e.g. up to 90 per cent at 20°C. Special measures should be taken for occasional condensation due to temperature changes. |