MOQ : 12
Control voltage: 3-32VDC
Control current: 5-25mA
Load voltage: 120: 60-1200VAC
Load current: 500A, 600A, 800A, 1000A
On-state voltage drop: AC<1.6VAC
On-off time: AC≤10ms
Off-state leakage current AC≤10mA
Dielectric withstand voltage: ≥2500VAC
Ambient temperature: -30~80℃
Dimensions: 500-600A: 115×53×60mm
800A: 125×63×70mm
1000A: 149×66×76mm
Installation form: Bolt installation
Description: Loads above 5A must be equipped with a radiator
Loads above 80A must be equipped with fan forced cooling or water cooling
| HHG1K Series | |
| Model | HHG1K-1/032F-120(SSR-DA) |
| Control voltage | 3-32VDC |
| Control current | 5-25mA |
| Load voltage | 120: 60-1200VAC |
| Load current | 500A, 600A, 800A, 1000A |
| On-state voltage drop | AC ≤ 1.6VAC |
| On-off time | AC≤ 10ms |
| Off-state leakage current | AC ≤ 10mA |
| Dielectric strength | ≥ 2500VAC |
| Ambient temp. | -30~80°C |
| Dimension | 500-600A:115×53×60mm 800A:125×63×70mm 1000A:149×66×76mm |
| Installation form | Bolt installation |
| Instruction | A radiator must be installed for loads above 5A; a fan of strong cooling or water cooling must be added for loads above 80A |
Q1. How much current margin is recommended when selecting a 500–1000A SSR?
Do not select at the load current. Add margin for inrush, ambient temperature and heat-sink quality, and a larger margin still for inductive loads. Resistive heaters need less margin than transformers or motors. Send the load, supply voltage and cabinet temperature, and our engineers will suggest a model.
Q2. Does a 1000A solid state relay need short-circuit protection?
Yes. An SSR is not short-circuit proof, and a fault current can destroy the output stage before an ordinary breaker trips. Use a fast-acting semiconductor fuse coordinated with the relay’s I²t withstand. Ask us for the I²t data for the chosen model when requesting a quote.
Q3. With ≤10mA off-state leakage, is the load truly de-energized?
No. An SSR is not an isolating device. Leakage of up to 10mA can keep small loads faintly energized, and the output remains connected to the line. For maintenance, use an upstream disconnect or contactor as well. This also matters for loads sensitive to small leakage currents.
Q4. Can the HHG1K be used on three-phase 380V, 480V or 690V systems?
The load voltage range is 60–1200VAC, which covers common three-phase supplies with headroom for transients. A three-phase heater bank typically uses one relay per controlled phase, depending on wiring. Tell us the supply voltage and connection, star or delta, and we will confirm the arrangement.
Q5. How is the correct HHG1K rating determined for heating control cabinets?
Send the heater power in kW, supply voltage, number of phases and cooling method. We will calculate the load current and suggest 500A, 600A, 800A or 1000A. The MOQ is 12 pcs, so single cabinets and project batches are both possible.
We has over 34 years of experience in this industry and has built a