Working power supply: DC24V; AC24V, AC220V, AC380V
Delay range: 1s, 5s, 10s, 30s, 60s, 120s, 180s, 5m
10m, 30m, 60m
Repeat error: ≤1%
Working mode: HHS8 (AH3-2): power-on delay
HHS8C (AH3-3, ST2P): power-on delay with instantaneous action
HHS8G: release delay
Contact form: HHS8G, HHS8 (AH3-2): two groups of delay contacts
HHS8C (AH3-3, ST2P): one group of delay and one group of instantaneous action
Contact capacity: 3A AC250V (resistive)
Dimensions: 40.5×50.5×82mm
Installation method: With different sockets and accessories, it can be installed in device type, panel type and 35mm guide rail
Working power supply: DC24V; AC24V, AC220V, AC380V
Delay range: NA: 1s/10s/1m/10m; NB: 3s/30s/3m/30m
NC: 6s/60s/6m/60m; ND: 1m/10m/1h/10h
NE: 3m/30m/3h/30h
Repeat error: ≤1%
Working mode: A mode: power-on delay; B mode: power-on delay with instantaneous action
Contact form: A mode: two groups of delay contacts; B mode: one group of delay and one group of instantaneous action
Contact capacity: 3A AC250V (resistive)
Dimensions: 40.5×50.5×82mm
Installation method: with different sockets and accessories, it can be installed in device type, panel type and 35mm guide rail
Specification | HHS8-1 | HHS8 | HHS8C | HHS8G | HHS8-N |
Operating power | AC380V,AC220V,AC110V,AC36V,AC24V, 50Hz;DC24V | ||||
Movement Forms | Power-on delay | Power-on delay (with momentary contact) | Release delay | Power-on delay | |
Delay Range | 1s、3s、5s、10s、30s、60s、3m、5m、10m、30m、60m、3h、5h、10h、12h | NA:1s/10s/1m/10m; NB:3s/30s/3m/30m; NC:6s/60s/6m/60m; ND:1m/10m/1h/10h; NE:3m/30m/3h/30h; | |||
Repetition error | ≤1% | ||||
Number of contacts | 1 set of time-delay contacts | Delay 2 conversion | 1 set of time-delay contacts 1 set of momentary contacts | Delay 2 conversion | A:Delay 2 conversion B: 1 set of time-delay contacts 1 set of momentary contacts |
Contact capacity | 3A AC250V (resistive) | ||||
Temperature range | -5°-40°C | ||||
Altitude | ≤2000m | ||||
Humidity | The relative humidity of the air is <50% at a maximum temperature of 40°C at the installation site, higher relative humidity may be permitted at lower temperatures, e.g. up to 90% at 20°C. Special measures should be taken for occasional condensation due to temperature changes. | ||||
Installation | Mounting on a device or 35mm rail with different bases | ||||
Conventional heating current Ith | 5A | ||||
Rated insulation voltage Ui | 400V | ||||
Rated impulse withstand voltage Uimp | 2.5KV | ||||
Ue/Ie | Rated Working Voltage Ue/Rated Working Current Ie:AC-15 Ue:AC250V,Ie:3A in each category of use. |