Input signal: Thermocouple: K, E; Thermal resistor: Pt100, Cu50
Measurement error: ≤1.0 level
Adjustment method: Three-position relay contact on-off control;
Hysteresis control (heating or cooling mode);
Setting method: Touch switch setting
Working power supply: AC220V, AC380V
Dimensions: 160×80×92mm
Opening size: 151×75mm
Installation method: Panel type
Typical applications: used in drying boxes, ovens, plastic machinery, etc.
Measuring signal: Thermocouple: K, E, J; Thermal resistor: Pt100, Cu50
Control mode: Two-position relay on-off control; PID adjustment relay on-off control;
PID adjustment drive SSR voltage control
Alarm mode: One set of alarm relay contact output
Two sets of alarm relay contact output
Working power supply: AC220V
Dimensions: 160×80×94mm
Opening size: 152×76mm
Additional function: RS485 communication
Typical application: Used in heating equipment such as drying boxes, ovens, plastic machinery, etc.
Remarks: Multiple sensor inputs can be set by the user
Input signal: Thermocouple: K, E; Thermal resistor: Pt100, Cu50
Measurement error: ≤1.0 level
Adjustment method: Three-position relay contact on-off control;
Hysteresis control (heating or cooling mode);
Setting method: Touch switch setting (instead of potentiometer setting)
Working power supply: AC220V, AC380V
Dimensions: 96×96×97mm
Opening size: 92×92mm
Installation method: Panel type
Typical applications: used in drying boxes, ovens, plastic machinery, etc.
Input signal: Thermocouple: K, E; Thermal resistor: Pt100, Cu50
Measurement error: ≤1.0 level
Adjustment method: Two-position relay contact on-off control;
Time proportional relay contact on-off control;
Setting method: Touch switch setting (instead of dial setting)
Working power supply: AC220V, AC380V
Dimensions: 96×96×99mm
Opening size: 92×92mm
Installation method: Panel type
Typical applications: used in drying boxes, ovens, plastic machinery, etc.
Measuring signal: Thermocouple: K, E, J; Thermal resistor: Pt100, Cu50
Control mode: Two-position relay on-off control;
PID adjustment relay on-off control;
PID adjustment drive SSR voltage control
Alarm mode: One set of alarm relay contact output;
Two sets of alarm relay contact output
Working power supply: AC220V
Dimensions: 96×96×91mm
Opening size: 92×92mm
Installation method: Panel type
Typical application: Used for heating equipment such as drying boxes, ovens, plastic machinery, etc.
Remarks: Multiple sensor inputs can be set by the user
Input signal: Thermocouple: K, E; Thermal resistor: Pt100, Cu50
Measurement error: ≤1.0 level
Adjustment method: Three-position relay contact on-off control;
Hysteresis control (heating or cooling mode);
Setting method: Touch switch setting (instead of potentiometer setting)
Working power supply: AC220V, AC380V
Dimensions: 72×72×90mm
Opening size: 68×68mm
Installation method: Panel type
Typical applications: used in drying boxes, ovens, plastic machinery, etc.
Measuring signal: Thermocouple: K, E, J; Thermal resistor: Pt100, Cu50
Control mode: Two-position relay on-off control;
PID adjustment relay on-off control;
PID adjustment drive SSR voltage control
Alarm mode: One set of alarm relay contact output;
Two sets of alarm relay contact output
Working power supply: AC220V
Dimensions: 72×72×91mm
Opening size: 68×68mm
Installation method: Panel type
Typical application: Used for heating equipment such as drying boxes, ovens, plastic machinery, etc.
Remarks: Multiple sensor inputs can be set by the user
Measuring signal: Thermocouple: K, E; Thermal resistor: Pt100, Cu50
Measurement error: ≤1.0 level
Control mode: Two-position relay contact on-off control;
Time proportional relay contact on-off control;
Working power supply: AC220V, AC380V
Dimensions: 72×72×72mm
Opening size: 68×68mm
Installation method: Panel type
Typical application: Used in drying boxes, ovens, plastic machinery and other heating equipment with general temperature control requirements
Input signal: Thermocouple: K, E; Thermal resistor: Pt100, Cu50
Measurement error: ≤1.0 level
Adjustment method: Two-position relay contact on-off control;
Time proportional relay contact on-off control;
Setting method: Touch switch setting
Working power supply: AC220V, AC380V
Dimensions: 48×96×82mm
Opening size: 45×92mm
Installation method: Panel type
Typical applications: Used in drying boxes, ovens, plastic machinery, etc.
Measuring signal: Thermocouple: K, E, J; Thermal resistor: Pt100, Cu50
Control mode: Two-position relay on-off control
PID adjustment relay on-off control
PID adjustment drive SSR voltage control
Alarm mode: One set of alarm relay contact output
Two sets of alarm relay contact output
Working power supply: AC220V
Dimensions: 48×96×91mm
Opening size: 45×92mm
Installation method: Panel type
Typical application: Used in heating equipment such as drying boxes, ovens, plastic machinery, etc.
Remarks: Multiple sensor inputs can be set by the user
Measuring signal: Thermocouple: K, E, J; Thermal resistor: Pt1:00, Cu50
Control mode: Two-position relay on-off control
PID adjustment relay on-off control
PID adjustment drive SSR voltage control
Alarm mode: One set of alarm relay contact output
Two sets of alarm relay contact output
Working power supply: AC220V
Dimensions: 96×48×90mm
Opening size: 92×44mm
Installation method: Panel type
Typical application: Used in heating equipment such as drying boxes, ovens, plastic machinery, etc.
Remarks: Multiple sensor inputs can be set by the user
Measuring signal: Thermocouple: K, E, J; Thermal resistor: Pt100, Cu50
Control mode: Two-position relay on-off control
PID adjustment relay on-off control
PID adjustment drive SSR voltage control
Alarm mode: One set of alarm relay contact output
Working power supply: AC220V
Dimensions: 48×48×107mm
Opening size: 45×45mm
Installation method: Panel type
Typical application: Used in heating equipment such as drying boxes, ovens, plastic machinery, etc.
Remarks: Multiple sensor inputs can be set by the user
XMT-121 series | ||||||
Model | XMT-121 | XMT-122 | XMT-121F1 | XMT-122F1 | XMT-121F2 | XMT-122F2 |
Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | |||||
Measurement error | ≤ 1.0 class | |||||
Adjustment mode | Three-position relay contact on-off control Hysteresis control (heating or cooling mode) | |||||
Setting mode | Touch switch setting | |||||
Supply voltage | AC220V, AC380V | |||||
Dimension | 160×80×92mm | |||||
Hole size | 151×75mm | |||||
Installation method | Panel type | |||||
Typical application | Used for drying boxes, ovens, plastic machines etc. |
XMTA-2000 series | ||||||
Model | XMTA-2201 | XMTA-2202 | XMTA-2201F1 | XMTA-2202F1 | XMTA-2201F2 | XMTA-2202F2 |
Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | |||||
Measurement error | ≤ 1.0 class | |||||
Adjustment mode | Three-position relay contact on-off control; hysteresis control (heating or cooling mode) | |||||
Setting mode | Touch switch setting | |||||
Supply voltage | AC220V, AC380V | |||||
Dimension | 96×96×97mm | |||||
Hole size | 92×92mm | |||||
Installation method | Panel type | |||||
Typical application | Used for heating equipment with general temperature control requirements such as drying ovens, ovens and plastic machines etc. |
XMTD-2000 series | |||||||||||
Model | XMTD-2201 | XMTD-2202 | XMTD-2201F1 | XMTD-2202F1 | XMTD-2201F2 | XMTD-2202F2 | XMTD-2203 | XMTD-2201B1 | XMTD-2202B1 | XMTD-2201B2 | XMTD-2202B2 |
Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | ||||||||||
Measurement error | ≤ 1.0 class | ||||||||||
Adjustment mode | Three-position relay contact on-off control; hysteresis control (heating or cooling mode) | ||||||||||
Setting mode | Touch switch setting | ||||||||||
Supply voltage | AC220V, AC380V | ||||||||||
Dimension | 72×72×90mm | ||||||||||
Hole size | 68×68mm | ||||||||||
Installation method | Panel type | ||||||||||
Typical application | Used for heating equipment with general temperature control requirements such as drying ovens, ovens and plastic machines etc. |
XMTA-3000 series | ||||
Model | XMTA-3001 | XMTA-3002 | XMTA-3301 | XMTA-3302 |
Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | |||
Measurement error | ≤ 1.0 class | |||
Adjustment mode | Two-position relay contact on-off control; time proportional relay contact on-off control | |||
Setting mode | Touch switch setting | |||
Supply voltage | AC220V, AC380V | |||
Dimension | 96×96×99mm | |||
Hole size | 92×92mm | |||
Installation method | Panel type | |||
Typical application | Used for heating equipment with general temperature control requirements such as drying ovens, ovens and plastic machines etc. |
XMTD-3000 series | |||
Model | XMTD-3001 | XMTD-3002 | XMTD-3003 |
Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | ||
Measurement error | ≤ 1.0 class | ||
Adjustment mode | Two-position relay contact on-off control; time proportional relay contact on-off control | ||
Setting mode | Touch switch setting | ||
Supply voltage | AC220V, AC380V | ||
Dimension | 72×72×90mm | ||
Hole size | 68×68mm | ||
Installation method | Panel type | ||
Typical application | Used for drying boxes, ovens, plastic machines etc |
XMTE-3000 series | ||||
Model | XMTE-3001 | XMTE-3002 | XMTE-3301 | XMTE-3302 |
Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | |||
Measurement error | ≤ 1.0 class | |||
Adjustment mode | Two-position relay contact on-off control; time proportional relay contact on-off control | |||
Setting mode | Touch switch setting | |||
Supply voltage | AC220V, AC380V | |||
Dimension | 48×96×82mm | |||
Hole size | 45×92mm | |||
Installation method | Panel type | |||
Typical application | Used for drying boxes, ovens, plastic machines etc. |
XMTG-3000 series | ||||
Model | XMTG-3001 | XMTG-3002 | XMTG-3301 | XMTG-3302 |
Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | |||
Measurement error | ≤ 1.0 class | |||
Adjustment mode | Two-position relay contact on-off control; time proportional relay contact on-off control | |||
Setting mode | Touch switch setting | |||
Supply voltage | AC220V, AC380V | |||
Dimension | 48×48×90mm | |||
Hole size | 45×45mm | |||
Installation method | Panel type | |||
Typical application | Used for heating equipment with general temperature control requirements such as drying ovens, ovens and plastic machines etc. |
XMT-5000 series | ||||||||||
Model | XMT-5011 | XMT-5012 | XMT-5211 | XMT-5212 | XMT-5231 | XMT-5232 | XMT-5401 | XMT-5402 | XMT-5511 | XMT-5512 |
Measurement signal | Thermocouple: K, E, J; thermal resistance: Pt100, Cu50 | |||||||||
Control mode | Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control | |||||||||
Alarm mode | 1 set of alarm relay contact outputs; 2 set of alarm relay contact outputs | |||||||||
Supply voltage | AC220V | |||||||||
Dimension | 160×80×94mm | |||||||||
Hole size | 152×76mm | |||||||||
Additional function | RS485 communication | |||||||||
Typical application | Used for heating equipment, such as drying boxes, ovens, plastic machines, etc |
XMTA-5000 series | ||||||||||
Model | XMTA-5011 | XMTA-5012 | XMTA-5211 | XMTA-5212 | XMTA-5231 | XMTA-5232 | XMTA-5401 | XMTA-5402 | XMTA-5511 | XMTA-5512 |
Measurement signal | Thermocouple: K, E, J; thermal resistance: Pt100, Cu50 | |||||||||
Control mode | Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control | |||||||||
Alarm mode | 1 set of alarm relay contact outputs; 2 set of alarm relay contact outputs | |||||||||
Supply voltage | AC220V | |||||||||
Dimension | 96×96×91mm | |||||||||
Hole size | 92×92mm | |||||||||
Installation method | Panel type | |||||||||
Typical application | Used for heating equipment, such as drying boxes, ovens, plastic machines, etc |
XMTD-5000 series | ||||||||||
Model | XMTD-5011 | XMTD-5012 | XMTD-5211 | XMTD-5212 | XMTD-5231 | XMTD-5232 | XMTD-5401 | XMTD-5402 | XMTD-5511 | XMTD-5512 |
Measurement signal | Thermocouple: K, E, J; thermal resistance: Pt100, Cu50 | |||||||||
Control mode | Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control | |||||||||
Alarm mode | 1 set of alarm relay contact outputs; 2 set of alarm relay contact outputs | |||||||||
Supply voltage | AC220V | |||||||||
Dimension | 72×72×91mm | |||||||||
Hole size | 68×68mm | |||||||||
Installation method | Panel type | |||||||||
Typical application | Used for heating equipment, such as drying boxes, ovens, plastic machines, etc |
XMTE-5000 series | ||||||||||
Model | XMTE-5011 | XMTE-5012 | XMTE-5211 | XMTE-5212 | XMTE-5231 | XMTE-5232 | XMTE-5401 | XMTE-5402 | XMTE-5511 | XMTE-5512 |
Measurement signal | Thermocouple: K, E, J; thermal resistance: Pt100, Cu50 | |||||||||
Control mode | Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control | |||||||||
Alarm mode | 1 set of alarm relay contact outputs; 2 set of alarm relay contact outputs | |||||||||
Supply voltage | AC220V | |||||||||
Dimension | 48×96×91mm | |||||||||
Hole size | 45×92mm | |||||||||
Installation method | Panel type | |||||||||
Typical application | Used for heating equipment, such as drying boxes, ovens, plastic machines, etc |
XMTF-5000 series | ||||||||||
Model | XMTF-5011 | XMTF-5012 | XMTF-5211 | XMTF-5212 | XMTF-5231 | XMTF-5232 | XMTF-5401 | XMTF-5402 | XMTF-5511 | XMTF-5512 |
Measurement signal | Thermocouple: K, E, J; thermal resistance: Pt100, Cu50 | |||||||||
Control mode | Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control | |||||||||
Alarm mode | 1 set of alarm relay contact outputs; 2 set of alarm relay contact outputs | |||||||||
Supply voltage | AC220V | |||||||||
Dimension | 96×48×90mm | |||||||||
Hole size | 92×44mm | |||||||||
Installation method | Panel type | |||||||||
Typical application | Used for heating equipment, such as drying boxes, ovens, plastic machines, etc |
XMTG-5000 series | ||||||||||
Model | XMTG-5011 | XMTG-5012 | XMTG-5211 | XMTG-5212 | XMTG-5231 | XMTG-5232 | XMTG-5401 | XMTG-5402 | XMTG-5511 | XMTG-5512 |
Measurement signal | Thermocouple: K, E, J; thermal resistance: Pt100, Cu50 | |||||||||
Control mode | Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control | |||||||||
Alarm mode | 1 set of alarm relay contact outputs | |||||||||
Supply voltage | AC220V | |||||||||
Dimension | 48×48×107mm | |||||||||
Hole size | 45×45mm | |||||||||
Installation method | Panel type | |||||||||
Typical application | Used for heating equipment, such as drying boxes, ovens, plastic machines, etc |
XMT-101 series | ||
Model | XMT-101 | XMT-102 |
Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | |
Measurement error | ≤ 1.0 class | |
Adjustment mode | Two-position relay contact on-off control Time proportional relay contact on-off control | |
Setting mode | Touch switch setting | |
Supply voltage | AC220V, AC380V | |
Dimension | 160×80×92mm | |
Hole size | 151×75mm | |
Installation method | Panel type | |
Typical application | Used for drying boxes, ovens, plastic machines etc. |
XMT-121 series | ||||||
Model | XMT-121 | XMT-122 | XMT-121F1 | XMT-122F1 | XMT-121F2 | XMT-122F2 |
Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | |||||
Measurement error | ≤ 1.0 class | |||||
Adjustment mode | Three-position relay contact on-off control Hysteresis control (heating or cooling mode) | |||||
Setting mode | Touch switch setting | |||||
Supply voltage | AC220V, AC380V | |||||
Dimension | 160×80×92mm | |||||
Hole size | 151×75mm | |||||
Installation method | Panel type | |||||
Typical application | Used for drying boxes, ovens, plastic machines etc. |
XMTD-D series | ||||||||
Model | XMTD-D3001 | XMTD-D3002 | XMTD-D3001F2 | XMTD-D3002F2 | XMTD-D3001G | XMTD-D3002G | XMTD-D3301 | XMTD-D3302 |
Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | |||||||
Measurement error | ≤ 1.0 class | |||||||
Adjustment mode | Two-position relay contact on-off control Time proportional relay contact on-off control | |||||||
Supply voltage | AC220V, AC380V | |||||||
Dimension | 72×72×72mm | |||||||
Hole size | 68×68mm | |||||||
Installation method | Panel type | |||||||
Typical application | Used for heating equipment with general temperature control requirements such as drying ovens, ovens and plastic machines etc. |
XMTG-1000 series | |
Model | XMTG-1003 |
Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 |
Control mode | Relay contact on-off control (hysteresis adjustable) |
Supply voltage | AC220V 50/60Hz |
Contact capacity | Passive AC220V 3A (resistive load) |
Dimension | 48×48×90mm |
Hole size | 45×45mm |
Installation method | Panel type |
Typical application | Used for heating equipment such as water heaters, incubators and heaters with general temperature control requirements |
We has over 34 years of experience in this industry and has built a