...
< Back
XMTA-2000 series
Model XMTA-2201 XMTA-2202 XMTA-2201F1 XMTA-2202F1 XMTA-2201F2 XMTA-2202F2
Input signal Thermocouple: K, E; thermal resistance: Pt100, Cu50
Measurement error ≤ 1.0 class
Adjustment mode Three-position relay contact on-off control; hysteresis control (heating or cooling mode)
Setting mode Touch switch setting
Supply voltage AC220V, AC380V
Dimension 96×96×97mm
Hole size 92×92mm
Installation method Panel type
Typical application Used for heating equipment with general temperature
control requirements such as drying ovens, ovens and plastic machines etc.

 

XMTD-2000 series
Model XMTD-2201 XMTD-2202 XMTD-2201F1 XMTD-2202F1 XMTD-2201F2 XMTD-2202F2 XMTD-2203 XMTD-2201B1 XMTD-2202B1 XMTD-2201B2 XMTD-2202B2
Input signal Thermocouple: K, E; thermal resistance: Pt100, Cu50
Measurement error ≤ 1.0 class
Adjustment mode Three-position relay contact on-off control; hysteresis control (heating or cooling mode)
Setting mode Touch switch setting
Supply voltage AC220V, AC380V
Dimension 72×72×90mm
Hole size 68×68mm
Installation method Panel type
Typical application Used for heating equipment with general temperature
control requirements such as drying ovens, ovens and plastic machines etc.

 

XMTA-3000 series
Model XMTA-3001 XMTA-3002 XMTA-3301 XMTA-3302
Input signal Thermocouple: K, E; thermal resistance: Pt100, Cu50
Measurement error ≤ 1.0 class
Adjustment mode Two-position relay contact on-off control;
time proportional relay contact on-off control
Setting mode Touch switch setting
Supply voltage AC220V, AC380V
Dimension 96×96×99mm
Hole size 92×92mm
Installation method Panel type
Typical application Used for heating equipment with general
temperature control requirements such as
drying ovens, ovens and plastic machines etc.

 

XMTD-3000 series
Model XMTD-3001 XMTD-3002 XMTD-3003
Input signal Thermocouple: K, E; thermal resistance: Pt100, Cu50
Measurement error ≤ 1.0 class
Adjustment mode Two-position relay contact on-off control;
time proportional relay contact on-off control
Setting mode Touch switch setting
Supply voltage AC220V, AC380V
Dimension 72×72×90mm
Hole size 68×68mm
Installation method Panel type
Typical application Used for drying boxes, ovens, plastic machines etc

 

XMTE-3000 series
Model XMTE-3001 XMTE-3002 XMTE-3301 XMTE-3302
Input signal Thermocouple: K, E; thermal resistance: Pt100, Cu50
Measurement error ≤ 1.0 class
Adjustment mode Two-position relay contact on-off control;
time proportional relay contact on-off control
Setting mode Touch switch setting
Supply voltage AC220V, AC380V
Dimension 48×96×82mm
Hole size 45×92mm
Installation method Panel type
Typical application Used for drying boxes, ovens, plastic machines etc.

 

XMTG-3000 series
Model XMTG-3001 XMTG-3002 XMTG-3301 XMTG-3302
Input signal Thermocouple: K, E; thermal resistance: Pt100, Cu50
Measurement error ≤ 1.0 class
Adjustment mode Two-position relay contact on-off control;
time proportional relay contact on-off control
Setting mode Touch switch setting
Supply voltage AC220V, AC380V
Dimension 48×48×90mm
Hole size 45×45mm
Installation method Panel type
Typical application Used for heating equipment with general temperature control requirements such as drying ovens, ovens and plastic machines etc.

 

XMT-5000 series
Model XMT-5011 XMT-5012 XMT-5211 XMT-5212 XMT-5231 XMT-5232 XMT-5401 XMT-5402 XMT-5511 XMT-5512
Measurement signal Thermocouple: K, E, J; thermal resistance: Pt100, Cu50
Control mode Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control
Alarm mode 1 set of alarm relay contact outputs; 2 set of alarm relay contact outputs
Supply voltage AC220V
Dimension 160×80×94mm
Hole size 152×76mm
Additional function RS485 communication
Typical application Used for heating equipment, such as drying boxes, ovens, plastic machines, etc

 

XMTA-5000 series
Model XMTA-5011 XMTA-5012 XMTA-5211 XMTA-5212 XMTA-5231 XMTA-5232 XMTA-5401 XMTA-5402 XMTA-5511 XMTA-5512
Measurement signal Thermocouple: K, E, J; thermal resistance: Pt100, Cu50
Control mode Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control
Alarm mode 1 set of alarm relay contact outputs; 2 set of alarm relay contact outputs
Supply voltage AC220V
Dimension 96×96×91mm
Hole size 92×92mm
Installation method Panel type
Typical application Used for heating equipment, such as drying boxes, ovens, plastic machines, etc

 

XMTD-5000 series
Model XMTD-5011 XMTD-5012 XMTD-5211 XMTD-5212 XMTD-5231 XMTD-5232 XMTD-5401 XMTD-5402 XMTD-5511 XMTD-5512
Measurement signal Thermocouple: K, E, J; thermal resistance: Pt100, Cu50
Control mode Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control
Alarm mode 1 set of alarm relay contact outputs; 2 set of alarm relay contact outputs
Supply voltage AC220V
Dimension 72×72×91mm
Hole size 68×68mm
Installation method Panel type
Typical application Used for heating equipment, such as drying boxes, ovens, plastic machines, etc

 

XMTE-5000 series
Model XMTE-5011 XMTE-5012 XMTE-5211 XMTE-5212 XMTE-5231 XMTE-5232 XMTE-5401 XMTE-5402 XMTE-5511 XMTE-5512
Measurement signal Thermocouple: K, E, J; thermal resistance: Pt100, Cu50
Control mode Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control
Alarm mode 1 set of alarm relay contact outputs; 2 set of alarm relay contact outputs
Supply voltage AC220V
Dimension 48×96×91mm
Hole size 45×92mm
Installation method Panel type
Typical application Used for heating equipment, such as drying boxes, ovens, plastic machines, etc

 

XMTF-5000 series
Model XMTF-5011 XMTF-5012 XMTF-5211 XMTF-5212 XMTF-5231 XMTF-5232 XMTF-5401 XMTF-5402 XMTF-5511 XMTF-5512
Measurement signal Thermocouple: K, E, J; thermal resistance: Pt100, Cu50
Control mode Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control
Alarm mode 1 set of alarm relay contact outputs; 2 set of alarm relay contact outputs
Supply voltage AC220V
Dimension 96×48×90mm
Hole size 92×44mm
Installation method Panel type
Typical application Used for heating equipment, such as drying boxes, ovens, plastic machines, etc

 

XMTG-5000 series
Model XMTG-5011 XMTG-5012 XMTG-5211 XMTG-5212 XMTG-5231 XMTG-5232 XMTG-5401 XMTG-5402 XMTG-5511 XMTG-5512
Measurement signal Thermocouple: K, E, J; thermal resistance: Pt100, Cu50
Control mode Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control
Alarm mode 1 set of alarm relay contact outputs
Supply voltage AC220V
Dimension 48×48×107mm
Hole size 45×45mm
Installation method Panel type
Typical application Used for heating equipment, such as drying boxes, ovens, plastic machines, etc

 

XMT-101 series
Model XMT-101 XMT-102
Input signal Thermocouple: K, E; thermal resistance: Pt100, Cu50
Measurement error ≤ 1.0 class
Adjustment mode Two-position relay contact on-off control
Time proportional relay contact on-off control
Setting mode Touch switch setting
Supply voltage AC220V, AC380V
Dimension 160×80×92mm
Hole size 151×75mm
Installation method Panel type
Typical application Used for drying boxes, ovens, plastic machines etc.

 

XMT-121 series
Model XMT-121 XMT-122 XMT-121F1 XMT-122F1 XMT-121F2 XMT-122F2
Input signal Thermocouple: K, E; thermal resistance: Pt100, Cu50
Measurement error ≤ 1.0 class
Adjustment mode Three-position relay contact on-off control
Hysteresis control (heating or cooling mode)
Setting mode Touch switch setting
Supply voltage AC220V, AC380V
Dimension 160×80×92mm
Hole size 151×75mm
Installation method Panel type
Typical application Used for drying boxes, ovens, plastic machines etc.

 

XMTD-D series
Model XMTD-D3001 XMTD-D3002 XMTD-D3001F2 XMTD-D3002F2 XMTD-D3001G XMTD-D3002G XMTD-D3301 XMTD-D3302
Input signal Thermocouple: K, E; thermal resistance: Pt100, Cu50
Measurement error ≤ 1.0 class
Adjustment mode Two-position relay contact on-off control
Time proportional relay contact on-off control
Supply voltage AC220V, AC380V
Dimension 72×72×72mm
Hole size 68×68mm
Installation method Panel type
Typical application Used for heating equipment with general temperature control requirements such as drying ovens, ovens and plastic machines etc.

 

XMTG-1000 series
Model XMTG-1003
Input signal Thermocouple: K, E; thermal resistance: Pt100, Cu50
Control mode Relay contact on-off control (hysteresis adjustable)
Supply voltage AC220V 50/60Hz
Contact capacity Passive AC220V 3A (resistive load)
Dimension 48×48×90mm
Hole size 45×45mm
Installation method Panel type
Typical application Used for heating equipment such as water heaters, incubators and heaters with general temperature control requirements

 

Related Product

We has over 34 years of experience in this industry and has built a
reputation for providing quality products and services at competitive prices.

Tell Us Your Requirements Questions Needs Ideas Plans