MOQ : 60
Input signal: Thermocouple: K, E; Thermal resistor: Pt100, Cu50
Measurement error: ≤1.0 level
Adjustment method: Three-position relay contact on-off control;
Hysteresis control (heating or cooling mode);
Setting method: Touch switch setting
Working power supply: AC220V, AC380V
Dimensions: 160×80×92mm
Opening size: 151×75mm
Installation method: Panel type
Typical applications: used in drying boxes, ovens, plastic machinery, etc.
Measuring signal: Thermocouple: K, E, J; Thermal resistor: Pt100, Cu50
Control mode: Two-position relay on-off control; PID adjustment relay on-off control;
PID adjustment drive SSR voltage control
Alarm mode: One set of alarm relay contact output
Two sets of alarm relay contact output
Working power supply: AC220V
Dimensions: 160×80×94mm
Opening size: 152×76mm
Additional function: RS485 communication
Typical application: Used in heating equipment such as drying boxes, ovens, plastic machinery, etc.
Remarks: Multiple sensor inputs can be set by the user
Input signal: Thermocouple: K, E; Thermal resistor: Pt100, Cu50
Measurement error: ≤1.0 level
Adjustment method: Three-position relay contact on-off control;
Hysteresis control (heating or cooling mode);
Setting method: Touch switch setting (instead of potentiometer setting)
Working power supply: AC220V, AC380V
Dimensions: 96×96×97mm
Opening size: 92×92mm
Installation method: Panel type
Typical applications: used in drying boxes, ovens, plastic machinery, etc.
Input signal: Thermocouple: K, E; Thermal resistor: Pt100, Cu50
Measurement error: ≤1.0 level
Adjustment method: Two-position relay contact on-off control;
Time proportional relay contact on-off control;
Setting method: Touch switch setting (instead of dial setting)
Working power supply: AC220V, AC380V
Dimensions: 96×96×99mm
Opening size: 92×92mm
Installation method: Panel type
Typical applications: used in drying boxes, ovens, plastic machinery, etc.
Measuring signal: Thermocouple: K, E, J; Thermal resistor: Pt100, Cu50
Control mode: Two-position relay on-off control;
PID adjustment relay on-off control;
PID adjustment drive SSR voltage control
Alarm mode: One set of alarm relay contact output;
Two sets of alarm relay contact output
Working power supply: AC220V
Dimensions: 96×96×91mm
Opening size: 92×92mm
Installation method: Panel type
Typical application: Used for heating equipment such as drying boxes, ovens, plastic machinery, etc.
Remarks: Multiple sensor inputs can be set by the user
Input signal: Thermocouple: K, E; Thermal resistor: Pt100, Cu50
Measurement error: ≤1.0 level
Adjustment method: Three-position relay contact on-off control;
Hysteresis control (heating or cooling mode);
Setting method: Touch switch setting (instead of potentiometer setting)
Working power supply: AC220V, AC380V
Dimensions: 72×72×90mm
Opening size: 68×68mm
Installation method: Panel type
Typical applications: used in drying boxes, ovens, plastic machinery, etc.
Measuring signal: Thermocouple: K, E, J; Thermal resistor: Pt100, Cu50
Control mode: Two-position relay on-off control;
PID adjustment relay on-off control;
PID adjustment drive SSR voltage control
Alarm mode: One set of alarm relay contact output;
Two sets of alarm relay contact output
Working power supply: AC220V
Dimensions: 72×72×91mm
Opening size: 68×68mm
Installation method: Panel type
Typical application: Used for heating equipment such as drying boxes, ovens, plastic machinery, etc.
Remarks: Multiple sensor inputs can be set by the user
Measuring signal: Thermocouple: K, E; Thermal resistor: Pt100, Cu50
Measurement error: ≤1.0 level
Control mode: Two-position relay contact on-off control;
Time proportional relay contact on-off control;
Working power supply: AC220V, AC380V
Dimensions: 72×72×72mm
Opening size: 68×68mm
Installation method: Panel type
Typical application: Used in drying boxes, ovens, plastic machinery and other heating equipment with general temperature control requirements
Input signal: Thermocouple: K, E; Thermal resistor: Pt100, Cu50
Measurement error: ≤1.0 level
Adjustment method: Two-position relay contact on-off control;
Time proportional relay contact on-off control;
Setting method: Touch switch setting
Working power supply: AC220V, AC380V
Dimensions: 48×96×82mm
Opening size: 45×92mm
Installation method: Panel type
Typical applications: Used in drying boxes, ovens, plastic machinery, etc.
Measuring signal: Thermocouple: K, E, J; Thermal resistor: Pt100, Cu50
Control mode: Two-position relay on-off control
PID adjustment relay on-off control
PID adjustment drive SSR voltage control
Alarm mode: One set of alarm relay contact output
Two sets of alarm relay contact output
Working power supply: AC220V
Dimensions: 48×96×91mm
Opening size: 45×92mm
Installation method: Panel type
Typical application: Used in heating equipment such as drying boxes, ovens, plastic machinery, etc.
Remarks: Multiple sensor inputs can be set by the user
Measuring signal: Thermocouple: K, E, J; Thermal resistor: Pt1:00, Cu50
Control mode: Two-position relay on-off control
PID adjustment relay on-off control
PID adjustment drive SSR voltage control
Alarm mode: One set of alarm relay contact output
Two sets of alarm relay contact output
Working power supply: AC220V
Dimensions: 96×48×90mm
Opening size: 92×44mm
Installation method: Panel type
Typical application: Used in heating equipment such as drying boxes, ovens, plastic machinery, etc.
Remarks: Multiple sensor inputs can be set by the user
Measuring signal: Thermocouple: K, E, J; Thermal resistor: Pt100, Cu50
Control mode: Two-position relay on-off control
PID adjustment relay on-off control
PID adjustment drive SSR voltage control
Alarm mode: One set of alarm relay contact output
Working power supply: AC220V
Dimensions: 48×48×107mm
Opening size: 45×45mm
Installation method: Panel type
Typical application: Used in heating equipment such as drying boxes, ovens, plastic machinery, etc.
Remarks: Multiple sensor inputs can be set by the user
| XMT-121 Series | ||||||
| Model | XMT-121 | XMT-122 | XMT-121F1 | XMT-122F1 | XMT-121F2 | XMT-122F2 |
| Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | |||||
| Measurement error | ≤ 1.0 class | |||||
| Adjustment mode | Three-position relay contact on-off control Hysteresis control (heating or cooling mode) | |||||
| Setting mode | Touch switch setting | |||||
| Supply voltage | AC220V, AC380V | |||||
| Dimension | 160×80×92mm | |||||
| Hole size | 151×75mm | |||||
| Installation method | Panel type | |||||
| Typical application | Used for drying boxes, ovens, plastic machines etc. | |||||
| XMT-5000 Series | ||||||||||
| Model | XMT-5011 | XMT-5012 | XMT-5211 | XMT-5212 | XMT-5231 | XMT-5232 | XMT-5401 | XMT-5402 | XMT-5511 | XMT-5512 |
| Measurement signal | Thermocouple: K, E, J; thermal resistance: Pt100, Cu50 | |||||||||
| Control mode | Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control | |||||||||
| Alarm mode | 1 set of alarm relay contact outputs; 2 set of alarm relay contact outputs | |||||||||
| Supply voltage | AC220V | |||||||||
| Dimension | 160×80×94mm | |||||||||
| Hole size | 152×76mm | |||||||||
| Additional function | RS485 communication | |||||||||
| Typical application | Used for heating equipment, such as drying boxes, ovens, plastic machines, etc | |||||||||
| XMTA-2000 Series | ||||||
| Model | XMTA-2201 | XMTA-2202 | XMTA-2201F1 | XMTA-2202F1 | XMTA-2201F2 | XMTA-2202F2 |
| Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | |||||
| Measurement error | ≤ 1.0 class | |||||
| Adjustment mode | Three-position relay contact on-off control; hysteresis control (heating or cooling mode) | |||||
| Setting mode | Touch switch setting | |||||
| Supply voltage | AC220V, AC380V | |||||
| Dimension | 96×96×97mm | |||||
| Hole size | 92×92mm | |||||
| Installation method | Panel type | |||||
| Typical application | Used for heating equipment with general temperature control requirements such as drying ovens, ovens and plastic machines etc. | |||||
| XMTA-3000 Series | ||||
| Model | XMTA-3001 | XMTA-3002 | XMTA-3301 | XMTA-3302 |
| Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | |||
| Measurement error | ≤ 1.0 class | |||
| Adjustment mode | Two-position relay contact on-off control; time proportional relay contact on-off control | |||
| Setting mode | Touch switch setting | |||
| Supply voltage | AC220V, AC380V | |||
| Dimension | 96×96×99mm | |||
| Hole size | 92×92mm | |||
| Installation method | Panel type | |||
| Typical application | Used for heating equipment with general temperature control requirements such as drying ovens, ovens and plastic machines etc. | |||
| XMTA-5000 Series | ||||||||||
| Model | XMTA-5011 | XMTA-5012 | XMTA-5211 | XMTA-5212 | XMTA-5231 | XMTA-5232 | XMTA-5401 | XMTA-5402 | XMTA-5511 | XMTA-5512 |
| Measurement signal | Thermocouple: K, E, J; thermal resistance: Pt100, Cu50 | |||||||||
| Control mode | Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control | |||||||||
| Alarm mode | 1 set of alarm relay contact outputs; 2 set of alarm relay contact outputs | |||||||||
| Supply voltage | AC220V | |||||||||
| Dimension | 96×96×91mm | |||||||||
| Hole size | 92×92mm | |||||||||
| Installation method | Panel type | |||||||||
| Typical application | Used for heating equipment, such as drying boxes, ovens, plastic machines, etc | |||||||||
| XMTD-2000 Series | |||||||||||
| Model | XMTD-2201 | XMTD-2202 | XMTD-2201F1 | XMTD-2202F1 | XMTD-2201F2 | XMTD-2202F2 | XMTD-2203 | XMTD-2201B1 | XMTD-2202B1 | XMTD-2201B2 | XMTD-2202B2 |
| Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | ||||||||||
| Measurement error | ≤ 1.0 class | ||||||||||
| Adjustment mode | Three-position relay contact on-off control; hysteresis control (heating or cooling mode) | ||||||||||
| Setting mode | Touch switch setting | ||||||||||
| Supply voltage | AC220V, AC380V | ||||||||||
| Dimension | 72×72×90mm | ||||||||||
| Hole size | 68×68mm | ||||||||||
| Installation method | Panel type | ||||||||||
| Typical application | Used for heating equipment with general temperature control requirements such as drying ovens, ovens and plastic machines etc. | ||||||||||
| XMTD-5000 Series | ||||||||||
| Model | XMTD-5011 | XMTD-5012 | XMTD-5211 | XMTD-5212 | XMTD-5231 | XMTD-5232 | XMTD-5401 | XMTD-5402 | XMTD-5511 | XMTD-5512 |
| Measurement signal | Thermocouple: K, E, J; thermal resistance: Pt100, Cu50 | |||||||||
| Control mode | Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control | |||||||||
| Alarm mode | 1 set of alarm relay contact outputs; 2 set of alarm relay contact outputs | |||||||||
| Supply voltage | AC220V | |||||||||
| Dimension | 72×72×91mm | |||||||||
| Hole size | 68×68mm | |||||||||
| Installation method | Panel type | |||||||||
| Typical application | Used for heating equipment, such as drying boxes, ovens, plastic machines, etc | |||||||||
| XMTD-D Series | ||||||||
| Model | XMTD-D3001 | XMTD-D3002 | XMTD-D3001F2 | XMTD-D3002F2 | XMTD-D3001G | XMTD-D3002G | XMTD-D3301 | XMTD-D3302 |
| Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | |||||||
| Measurement error | ≤ 1.0 class | |||||||
| Adjustment mode | Two-position relay contact on-off control Time proportional relay contact on-off control | |||||||
| Supply voltage | AC220V, AC380V | |||||||
| Dimension | 72×72×72mm | |||||||
| Hole size | 68×68mm | |||||||
| Installation method | Panel type | |||||||
| Typical application | Used for heating equipment with general temperature control requirements such as drying ovens, ovens and plastic machines etc. | |||||||
| XMTE-3000 Series | ||||
| Model | XMTE-3001 | XMTE-3002 | XMTE-3301 | XMTE-3302 |
| Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | |||
| Measurement error | ≤ 1.0 class | |||
| Adjustment mode | Two-position relay contact on-off control; time proportional relay contact on-off control | |||
| Setting mode | Touch switch setting | |||
| Supply voltage | AC220V, AC380V | |||
| Dimension | 48×96×82mm | |||
| Hole size | 45×92mm | |||
| Installation method | Panel type | |||
| Typical application | Used for drying boxes, ovens, plastic machines etc. | |||
| XMTE-5000 Series | ||||||||||
| Model | XMTE-5011 | XMTE-5012 | XMTE-5211 | XMTE-5212 | XMTE-5231 | XMTE-5232 | XMTE-5401 | XMTE-5402 | XMTE-5511 | XMTE-5512 |
| Measurement signal | Thermocouple: K, E, J; thermal resistance: Pt100, Cu50 | |||||||||
| Control mode | Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control | |||||||||
| Alarm mode | 1 set of alarm relay contact outputs; 2 set of alarm relay contact outputs | |||||||||
| Supply voltage | AC220V | |||||||||
| Dimension | 48×96×91mm | |||||||||
| Hole size | 45×92mm | |||||||||
| Installation method | Panel type | |||||||||
| Typical application | Used for heating equipment, such as drying boxes, ovens, plastic machines, etc | |||||||||
| XMTF-5000 Series | ||||||||||
| Model | XMTF-5011 | XMTF-5012 | XMTF-5211 | XMTF-5212 | XMTF-5231 | XMTF-5232 | XMTF-5401 | XMTF-5402 | XMTF-5511 | XMTF-5512 |
| Measurement signal | Thermocouple: K, E, J; thermal resistance: Pt100, Cu50 | |||||||||
| Control mode | Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control | |||||||||
| Alarm mode | 1 set of alarm relay contact outputs; 2 set of alarm relay contact outputs | |||||||||
| Supply voltage | AC220V | |||||||||
| Dimension | 96×48×90mm | |||||||||
| Hole size | 92×44mm | |||||||||
| Installation method | Panel type | |||||||||
| Typical application | Used for heating equipment, such as drying boxes, ovens, plastic machines, etc | |||||||||
| XMTG-3000 Series | ||||
| Model | XMTG-3001 | XMTG-3002 | XMTG-3301 | XMTG-3302 |
| Input signal | Thermocouple: K, E; thermal resistance: Pt100, Cu50 | |||
| Measurement error | ≤ 1.0 class | |||
| Adjustment mode | Two-position relay contact on-off control; time proportional relay contact on-off control | |||
| Setting mode | Touch switch setting | |||
| Supply voltage | AC220V, AC380V | |||
| Dimension | 48×48×90mm | |||
| Hole size | 45×45mm | |||
| Installation method | Panel type | |||
| Typical application | Used for heating equipment with general temperature control requirements such as drying ovens, ovens and plastic machines etc. | |||
| XMTG-5000 Series | ||||||||||
| Model | XMTG-5011 | XMTG-5012 | XMTG-5211 | XMTG-5212 | XMTG-5231 | XMTG-5232 | XMTG-5401 | XMTG-5402 | XMTG-5511 | XMTG-5512 |
| Measurement signal | Thermocouple: K, E, J; thermal resistance: Pt100, Cu50 | |||||||||
| Control mode | Two-position relay on-off control; PID regulation relay on-off control; PID regulation drive SSR voltage control | |||||||||
| Alarm mode | 1 set of alarm relay contact outputs | |||||||||
| Supply voltage | AC220V | |||||||||
| Dimension | 48×48×107mm | |||||||||
| Hole size | 45×45mm | |||||||||
| Installation method | Panel type | |||||||||
Q1: What industries use XMT temperature controllers most?
A1: XMT temperature controllers are commonly used in industrial heating applications, such as drying boxes, ovens, plastic machinery, and other temperature-controlled equipment.
Q2: Difference between temperature sensor and controller?
A2: A temperature sensor (such as a thermocouple or Pt100) measures temperature, while a temperature controller receives the signal and controls heating or cooling to maintain the set temperature.
Q3: How accurate is XMT temperature control?
A3: The XMT Series offers a measurement accuracy of ≤ 1.0 level, providing stable and reliable temperature control for industrial use.
Q4: Does XMT support OEM customization?
A4: OEM customization availability depends on the manufacturer and order requirements. For specific customization options, it is recommended to contact us directly.
We has over 34 years of experience in this industry and has built a
reputation for providing quality products and services at competitive prices.