HCS series | |
Model | HCS-15 |
Input spec. | 1-circuit temperature and humidity input module (built-in) |
Measuring range | Temp.: -19°C~99°C Humidity: 0%~ 99% RH |
Basic error | Temp.: +1.5°C(0°C~ 100°C), Humidity: +5% RH(10%~99% ) |
Resolution | Temp.: 1°C Humidity: 1%RH |
Supply voltage | 20VAC, 50/60Hz, default dehumidification power 15W, please specify for any other power |
Recommended dehumidification space | 0.5~1m³ |
Work environment | Non-corrosive environment with temperature of 0~50°C and humidity ≤ 85% RH |
Pipe length | High temperature resistant silicone hose, 1m standard length, please specify for any other size |
HCS series | |
Model | HCS-30 |
Supply voltage | 220VAC, 50Hz, standby power consumption 5VA |
Measuring range | Temp.: -19°C~99°C; humidity: 0%~99% RH |
Basic error | Temp.: ±0.5°C (10°C~50°C)±1.5°C (0°C~99°C) Humidity: ±3% RH(10% RH~90% RH) ±5% RH(0% RH~99% RH) |
Resolution | Temp.: 1°C , humidity: 1% RH |
Control mode | Humidity: high humidity control; temperature: low or high temperature control (optional); temperature output: 1-circuit relay output (passive), 250VAC/3A or 30VDC/3A |
Fault output | One-circuit passive fault output |
Comm. mode | RS485 comm. (Modbus protocol) |
Work environment | Non-corrosive environment with temperature of 0~50°C and humidity ≤ 85% RH |
Working condition water output | Default dehumidification power 30W, please specify for any other power |
Recommended dehumidification space | 1~2m³ |
Pipe length | High temperature resistant silicone hose, 1m standard length, please specify for any other size |