Control voltage: 5-32VDC
Control current: 10-45mA
Load voltage: 20: 12-250VDC
Load current: 10A, 15A, 20A, 25A, 30A, 40A, 60A
On-state voltage drop: DC≤ 1.2VDC
On-off time: DC≤ 5ms
Off-state leakage current DC≤ 5mA
Dielectric withstand voltage: ≥ 2000VAC
Ambient temperature: -30~80℃
Dimensions: 60×45×29mm
Installation form: Bolt installation
Description: Loads above 10A must be equipped with a heat sink
Control voltage: 3-32VDC
Control current: 6-25mA
Load voltage: 22: 24-240VAC, 38: 24-440VAC
Load current: 10A, 15A, 20A, 25A, 30A, 40A, 60A, 80A, 100A
On-state voltage drop: AC≤ 1.6VAC
On-off time: AC≤ 10ms
Off-state leakage current AC≤ 10mA
Dielectric withstand voltage: ≥ 2500VAC
Ambient temperature: -30~80℃
Dimensions: 60×45×29mm
Installation form: Bolt installation
Description: Loads above 5A must be equipped with a radiator;
Loads above 80A must be cooled by fans or water
Control voltage: 3-32VDC
Control current: 6-35mA
Load voltage: 22: 24-240VAC, 38: 24-440VAC/span>
Load current: 1A
On-state voltage drop: AC≤1.6VAC
On-off time: AC≤10ms
Off-state leakage current: AC≤10mA
Dielectric withstand voltage: ≥ 1500VAC
Ambient temperature: -30~80℃
Dimensions: 32.5×17.5×18.5mm
Installation form: DIP
Description: Install next to the heat dissipation window with good ventilation
Control voltage: 3-32VDC
Control current: 6-25mA
Load voltage: 22: 24-240VAC, 38: 24-440VAC
Load current: 2A, 3A, 4A
On-state voltage drop: AC ≤ 1.6VAC
On-off time: AC≤10ms
Off-state leakage current: AC≤10mA
Dielectric withstand voltage: ≥ 1500VAC
Ambient temperature: -30~80℃
Dimensions: 34×26.5×18mm
Installation form: DIP
Description: Install next to a heat dissipation window with good ventilation
Control voltage: 3-32VDC
Control current: 6-25mA
Load voltage: 22: 24-240VAC, 38: 24-440VAC
Load current: 5A
On-state voltage drop: AC≤1.6VAC
On-off time: AC≤10ms
Off-state leakage current: AC≤10mA
Dielectric withstand voltage: ≥1500VAC
Ambient temperature: -30~80℃
Dimensions: 42×31×20mm
Installation form: DIP
Description: Install next to the heat dissipation window with good ventilation
Control voltage: 90-250VAC
Control current: 6-20mA
Load voltage: 22: 24-240VAC
Load current: 10A, 15A, 20A, 25A, 30A, 40A, 60A, 80A, 100A
On-state voltage drop: AC≤ 1.6VAC
On-off time: AC≤ 10ms
Off-state leakage current AC≤ 10mA
Dielectric withstand voltage: ≥ 2500VAC
Ambient temperature: -30~80℃
Dimensions: 60×45×29mm
Installation: Bolt installation
Description: A heat sink must be installed for loads above 5A;
A fan forced cooling or water cooling must be added for loads above 80A
Control voltage: 90-250VAC
Control current: 6-20mA
Load voltage: 38: 24-440VAC
Load current: 10A, 15A, 20A, 25A, 30A, 40A, 60A, 80A, 100A
On-state voltage drop: AC≤ 1.6VAC
On-off time: AC≤ 10ms
Off-state leakage current AC≤ 10mA
Dielectric withstand voltage: ≥ 2500VAC
Ambient temperature: -30~80℃
Dimensions: 60×45×29mm
Installation: Bolt installation
Description: A heat sink must be installed for loads above 5A;
A fan forced cooling or water cooling must be added for loads above 80A
Control voltage: 3-32VDC
Control current: 16-30mA
Load voltage: 24-440VAC
Load current: 10A, 15A, 20A, 25A, 30A, 40A, 60A, 80A, 100A, 120A
On-state voltage drop: AC≤ 1.6VAC
On-off time: AC≤ 10ms
Off-state leakage current: AC≤ 10mA
Dielectric withstand voltage: ≥ 2500VAC
Ambient temperature: -30~80℃
Dimensions: 106×75×40mm
Installation form: Bolt installation
Description: A heat sink must be installed for loads above 5A;
A fan forced cooling or water cooling must be added for loads above 80A
Control voltage: 90-250VAC
Control current: 8-30mA
Load voltage: 24-440VAC
Load current: 10A, 15A, 20A, 25A, 30A, 40A, 60A, 80A, 100A, 120A
On-state voltage drop: AC≤ 1.6VAC
On-off time: AC≤ 10ms
Off-state leakage current: AC≤ 10mA
Dielectric withstand voltage: ≥ 2500VAC
Ambient temperature: -30~80℃
Dimensions: 106×75×40mm
Installation form: Bolt installation
Description: A heat sink must be installed for loads above 5A;
A fan forced cooling or water cooling must be added for loads above 80A
HHG1-0 series | |||||
Model | HHG1-0/032F-06 100Z (SSR-DD) | HHG1-0/032F-20 2Z (SSR-DD) HHG1-0/032F-20 3Z (SSR-DD) HHG1-0/032F-20 4Z (SSR-DD) | HHG1-0/032F-20 1Z (SSR-DD) | HHG1-0/032F-20 5Z (SSR-DD) | HHG1-0/032F-20 10Z (SSR-DD) HHG1-0/032F-20 15Z (SSR-DD) HHG1-0/032F-20 20Z (SSR-DD) HHG1-0/032F-20 25Z (SSR-DD) HHG1-0/032F-20 30Z (SSR-DD) HHG1-0/032F-20 40Z (SSR-DD) HHG1-0/032F-20 60Z (SSR-DD) |
Control voltage | 5-32VDC | 3-32VDC | 5-32VDC | ||
Control current | 10-45mA | 6-25mA | 10-45mA | ||
Load voltage | 06: 5-60VDC | 20: 12-250VDC | |||
Load current | 100A | 2A, 3A, 4A | 1A | 5A | 10A, 15A, 20A, 25A, 30A, 40A, 60A |
On-state voltage drop | ≤ 1.2VDC | DC ≤ 1.2V AC ≤ 1.6VAC | ≤ 1.2VDC | ||
On-off time | ≤ 5ms | DC ≤ 5ms AC ≤ 10ms | ≤ 5ms | ||
Off-state leakage current | ≤ 5mA | DC ≤ 5mA AC ≤ 10mA | ≤ 5mA | ||
Dielectric strength | ≥ 2000VAC | ≥ 1500VAC | ≥ 2000VAC | ||
Ambient temp. | -30~80°C | -30~80°C | -30~80°C | ||
Dimension | 60×45×29mm | 34×26.5×18mm | 32.5×17.5×18.5mm | 42×31×20mm | 60×45×29mm |
Installation form | Bolt installation | Dual line direct plug-in | Bolt installation | ||
Instruction | A radiator must be installed for loads above 5A | Installed next to well ventilated heat dissipation window | A radiator must be installed for loads above 5A |
HHG1-1 series | |||||
Model | HHG1-1/032F-22 (SSR-DA) HHG1-1/032F-38 (SSR-DA) | HHG1-1/250F-22 (SSR-AA) HHG1-1/250F-38 (SSR-AA) | |||
Control voltage | 3-32VDC | 90-250VAC | |||
Control current | 6-25mA | 6-20mA | |||
Load voltage | 22: 24-240VAC 38: 24-440VAC | ||||
Load current | 10A, 15A, 20A, 25A, 30A, 40A, 60A, 80A, 100A | 1A | 5A | 2A、3A、4A | 10A, 15A, 20A, 25A, 30A, 40A, 60A, 80A, 100A |
On-state voltage drop | ≤ 1.6VAC | DC ≤ 1.2V AC ≤ 1.6VAC | ≤ 1.6VAC | ||
On-off time | ≤ 10ms | DC ≤ 5ms AC ≤ 10ms | ≤ 10ms | ||
Off-state leakage current | ≤ 10mA | DC ≤ 5mA AC ≤ 10mA | ≤ 10mA | ||
Dielectric strength | ≥ 2500VAC | ≥ 1500VAC | ≥ 2500VAC | ||
Ambient temp. | -30~80°C | -30~80°C | -30~80°C | ||
Dimension | 60×45×29mm | 32.5×17.5×18.5mm | 42×31×20mm | 34×26.5×18mm | 60×45×29mm |
Installation form | Bolt installation | Dual line direct plug-in | Bolt installation | ||
Instruction | A radiator must be installed for loads above 5A; a fan of strong cooling or water cooling must be added for loads above 80A | Installed next to well ventilated heat dissipation window | A radiator must be installed for loads above 5A; a fan of strong cooling or water cooling must be added for loads above 80A |
HHG1-2 series | |
Model | HHG1-2/032F-38 (SSR-DA) |
Control voltage | 3-32VDC |
Control current | Single circuit < 15mA |
Load voltage | 38:24-440VAC |
Load current | 10A, 15A, 20A, 25A, 30A, 40A(single-circuit) |
On-state voltage drop | ≤ 1.6VAC |
On-off time | ≤ 10ms |
Off-state leakage current | ≤ 10mA |
Dielectric strength | ≥ 2500VAC |
Ambient temp. | -30~80°C |
Dimension | 57×44×30mm |
Installation form | Bolt installation |
Instruction | A radiator must be installed for loads above 5A |
HHG1-3 series | ||
Model | HHG1-3/032F-38 (SSR-DA) | HHG1-3/250F-38 (SSR-AA) |
Control voltage | 3-32VDC | 90-250VAC |
Control current | 16-30mA | 8-30mA |
Load voltage | 24-440VAC | |
Load current | 10A, 15A, 20A, 25A, 30A, 40A, 60A, 80A, 100A, 120A | |
On-state voltage drop | AC ≤ 1.6VAC | |
On-off time | AC ≤ 10ms | |
Off-state leakage current | AC ≤ 10mA | |
Dielectric strength | ≥ 2500VAC | |
Ambient temp. | -30~80°C | |
Dimension | 106×75×40mm | |
Installation form | Bolt installation | |
Instruction | A radiator must be installed for loads above 5A; a fan of strong cooling or water cooling must be added for loads above 80A |